In today’s market, it is imperative to be knowledgeable and have an edge over the competition. ACI members have it…they are engaged, informed, and stay up to date by taking advantage of benefits that ACI membership provides them.
Read more about membership
Learn More
Become an ACI Member
Founded in 1904 and headquartered in Farmington Hills, Michigan, USA, the American Concrete Institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensus-based standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete design, construction, and materials, who share a commitment to pursuing the best use of concrete.
American Concrete Institute 38800 Country Club Dr. Farmington Hills, MI 48331-3439 USA
Phone: 1.248.848.3700 Fax: 1.248.848.3701 Staff Directory
Email Support
Feedback via Email Phone: 1.248.848.3800
Home > Publications > International Concrete Abstracts Portal
The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.
Title: Behavior of a New Steel-Concrete Hybrid Frame System
Author(s): R. S. Aboutaha
Publication: Special Publication
Volume: 196
Issue:
Appears on pages(s): 175-188
Keywords: confinement;ductility; headed bars; plastic hinge; reinforced concrete; seismic resistance; shear resistance; steel tube
Date: 10/1/2000
Abstract:the reinforcing bars and the surrounding concrete within the beam column joint. This paper introduces a new innovative steel-concrete composite frame system with controlled plastic mechanism. This frame system consists of steel tubed reinforced concrete (STRC) columns, and ordinary reinforced concrete beams with relocated plastic hinges. Beam plastic hinges are relocated by the use of straight headed bars. The STRC column is an ordinary reinforced concrete column but, transversely reinforced with light ordinary ties and a thin steel tube. Compared to concrete filled tube column (CFT), the steel tube of STRC column transfers no axial load, provides better confinement, and consequently, increases column ductility. In this paper, experimental investigation of two full scale STRC columns and two beams with and without headed bars are presented. Test results suggest that STRC columns and beams with relocated plastic hinge regions could offer a more ductile structural frame system for medium and high rise buildings in zones of high seismicity.