Title:
Tie Requirements for Reinforced Concrete Columns
Author(s):
B. Bresler and P. H. Gilbert
Publication:
Journal Proceedings
Volume:
58
Issue:
11
Appears on pages(s):
555-570
Keywords:
none
DOI:
10.14359/7997
Date:
11/1/1961
Abstract:
Mechanism of failure of reinforced concrete columns with lateral ties is described. Rational criteria for spacing and size of lateral ties are derived, and pilot tests verifying some of these criteria are described.