In today’s market, it is imperative to be knowledgeable and have an edge over the competition. ACI members have it…they are engaged, informed, and stay up to date by taking advantage of benefits that ACI membership provides them.
Read more about membership
Learn More
Become an ACI Member
Founded in 1904 and headquartered in Farmington Hills, Michigan, USA, the American Concrete Institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensus-based standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete design, construction, and materials, who share a commitment to pursuing the best use of concrete.
American Concrete Institute 38800 Country Club Dr. Farmington Hills, MI 48331-3439 USA
Phone: 1.248.848.3700 Fax: 1.248.848.3701 Staff Directory
Email Support
Feedback via Email Phone: 1.248.848.3800
Home > Publications > International Concrete Abstracts Portal
The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.
Title: Electrochemical testing of corrosion process in a reinforcement of a cracked concrete
Author(s): P. Falewicz, M. Klakočar-Ciepacz, S. Kuczkowska, A. Zybura
Publication: KILW
Volume: 51
Issue: 4
Appears on pages(s): 561-585
Keywords: corrosion,reinforcement
Date: 10/1/2005
Abstract:This paper presents the results of an extensive electrochemical research work that was aimed at reproducing as close as possible the corrosive processes that take place along the rebar which reinforces concrete elements as being treated by mechanical loads and aggressive chloride ions. The tests have been carried out both on cuboidal blocks, reinforced by a plain rebar and on identical blocks reinforced by a ribbed bar. Prior to the measurements each sample had been subjected to a cyclic action of the aggressive environment by being exposed through 3.5 hour's time to the 3.1% strong solution of sodium chloride, and then to a drying process through 68.5 hour's time at the ambient temperature. The electrochemical tests embraced the measuring of the distribution of stationary potential, and that of the electrochemical polarization using the method adapted to the conditions inside the concrete elements. They made it possible to specify among other things the density of corrosion current and the resistance of polarization, which are used for measuring the corrosion process rate. We did find out that portions with a decreased potential did appear around each crack of the covering concrete. The strongest stimulation of electrochemical processes occurred in the presence of several cracks. Values of the corrosive potential, corrosion current density and polarization resistance did not depend on a width of the cracks. Actual values of the corrosion current density were lower in the samples reinforced with ribbed rebars than in the samples reinforced with plain rebars. This result evidences better protective properties of a concrete covering if a ribbed reinforcement is used.