In today’s market, it is imperative to be knowledgeable and have an edge over the competition. ACI members have it…they are engaged, informed, and stay up to date by taking advantage of benefits that ACI membership provides them.
Read more about membership
Learn More
Become an ACI Member
Founded in 1904 and headquartered in Farmington Hills, Michigan, USA, the American Concrete Institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensus-based standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete design, construction, and materials, who share a commitment to pursuing the best use of concrete.
Staff Directory
ACI World Headquarters 38800 Country Club Dr. Farmington Hills, MI 48331-3439 USA Phone: 1.248.848.3800 Fax: 1.248.848.3701
ACI Middle East Regional Office Second Floor, Office #207 The Offices 2 Building, One Central Dubai World Trade Center Complex Dubai, UAE Phone: +971.4.516.3208 & 3209
ACI Resource Center Southern California Midwest Mid Atlantic
Feedback via Email Phone: 1.248.848.3800
Home > Publications > International Concrete Abstracts Portal
The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.
Showing 1-5 of 35 Abstracts search results
Document:
21-412
Date:
September 1, 2022
Author(s):
Naseeruddin Haris and Sangeeta Gadve
Publication:
Materials Journal
Volume:
119
Issue:
5
Abstract:
Corrosion of steel reinforcing bars in reinforced concrete (RC) structures is a matter of concern among practicing engineers and researchers are perpetually working over it. The development length of reinforcing bars at joints of RC structural frames are more prone to severe corrosion. Due to this, the design stress that needs to be developed in reinforcing bars is largely reduced. In addition, the development lengths of reinforcing bars create congestion at frame joints. This paper is an attempt to overcome these issues. In this paper, an epoxy-grouted nut coupler system is proposed that generates the required design stress in reinforcing bars with a very short development length at end anchorages, due to which congestion of the reinforcing bar at the joints can be avoided. The experimental investigation on the effect of corrosion on bond strength and development length of reinforcing bar in this epoxy-grouted nut coupler is also carried out by performing pullout tests. Statistical models are developed to predict the bond strength between the coupler and reinforcing bar corroded to different levels. This epoxy-grouted nut coupler is an effective tool for developing required stress in reinforcing bars by reducing the actual development length of reinforcing bars in the case of new structures. It is also useful and convenient in regeneration of stress in reinforcing bars at end anchorages that has been lost in corrosion-damaged structures.
DOI:
10.14359/51735977
21-387
July 1, 2022
Nghia P. Tran, Chamila Gunasekara, David W. Law, Shadi Houshyar, and Sujeeva Setunge
4
In this study, carpet waste fibers—namely, polypropylene (PP) and polytrimethylene terephthalate (PTT) in the form of mono microfibers and hybrid combinations—were studied. The optimization of mono fiber parameters for fiber content (0.1, 0.3, and 0.5%) and length (6, 12, and 24 mm [0.236, 0.742, and 0.945 in.]) were conducted to achieve the optimum strength properties and minimize drying shrinkage. The microstructure, pore structure, and fiber-matrix interfacial properties of the optimized samples were characterized at 7, 28, and 90 days by means of scanning electron microscopy (SEM), X-ray micro-computed tomography (CT), and nanoindentation. The research data revealed that the inclusion of either the optimized mono PP fiber (υf = 0.5% and l = 12 mm [0.472 in.]) or PTT fiber (υf = 0.1% and l = 12 mm [0.472 in.]) improved the compressive strength of 4.3% and 16.1%, and the flexural strength by 11.5% and 9.2% at 28 days, respectively. Hybrid carpet fibers (0.4% PP + 0.1% PTT) provided a greater enhancement in compressive strength of 6.6%, and flexural strength by 13% at 28 days. Drying shrinkage mitigation of mortar over 120 days was recorded as 18.4, 22.3, and 25.8%, corresponding to the addition of 0.5% PP fibers, 0.1% PTT fibers, and hybrid PP/PTT carpet fibers. A pore-refining effect was also observed for mortars with 0.5% PP and hybrid PP/PTT carpet microfibers. The SEM images indicated that the trilobal cross-sectional shape of PTT carpet fibers had a stronger anchoring effect with cement hydrates than the rounded shape of PP carpet fibers. Nanoindentation identified the thickness of the fiber-matrix interfacial transition zone (ITZ) as approximately 15 μm (5.9 × 10–4 in.) for both mono PP and PTT fibers. Approximately 50% of the phases in the vicinity of the fiber-matrix interface comprised a porous structure at 7 days. However, the hydration of clinker over the 90-day period promoted the formation of calcium-silicate-hydrate (C-S-H) and portlandite to form a dense microstructure.
10.14359/51734688
20-443
September 1, 2021
Julian Carrillo, José A. Ortiz-Lozano, and Juan G. Rueda-Bayona
118
The evaluation of the mechanical properties of steel fiber-reinforced concrete (SFRC) with different types of fibers and dosages endorses new design recommendations for using several types of construction materials for structural elements. The double-punch test (DPT) offers procedural and economic advantages for evaluating the indirect tensile strength of the SFRC. The objective of this paper is to show and discuss the results of the mechanical characterization obtained experimentally for SFRC using the DPT, with different types of anchorage and fiber dosages. The variables of the study were the dosage of steel fibers (20, 40, and 60 kg/m3) and the number of hooks at the ends of the fiber (1, 1.5, and 2 hooks). The paper develops empirical models for predicting the tensile strength, residual strength, and toughness of SFRC subjected to the DPT without resorting to experimental tests. The models were developed considering the trends of 385 results: 108 from 40 DPTs measured in this study, and 277 from 23 DPTs available in the literature.
10.14359/51732932
16-012
July 1, 2017
Christoph Mahrenholtz and Rolf Eligehausen
114
The load transfer within joints of reinforced concrete elements can strongly influence the behavior of the structure. Additionally, cracks play an important role—they develop due to bending-induced tensile stresses in concrete and meander along the starter bars anchored in joints. The performance of joints becomes even more relevant under seismic loading conditions, whereby the reinforcing bars are subjected to cyclic loading and, at the same time, cyclic opening and closing of the cracks intercepting the starter bars. Such load and crack cycling may significantly influence the load and displacement capacity of starter bar anchorages. Experimental tests were carried out to verify a generic bond model to describe the bond stress-slip relationship under these seismic conditions. This seismic bond model should allow the realistic numerical simulation of seismically loaded reinforced concrete structures even if joints are designed with starter bars shorter than the development length.
10.14359/51689777
15-219
January 1, 2017
Anthony J. Lamanna
1
Concrete screw anchors can be susceptible to stress-induced hydrogen embrittlement cracking because they are case hardened and often coated. Hydrogen attack can result in decreased tensile ductility and decreased fracture stress at the root, which is where the threads meet the core. Currently, Acceptance Criteria 193 (AC 193) requires that two types of tests are conducted to qualify screw fasteners for stress-induced hydrogen embrittlement cracking under service conditions: 1) Method A, which is a test subjecting a concrete screw installed in concrete to a sustained tensile load while in an aggressive environment; and 2) Method B, which is a bending test on the threaded portion of the fastener while in an aggressive environment. This study examines Method A and Method B qualification test data obtained from three manufacturers for five different diameters and 11 different lengths. The comparison of the test results for the two methods shows that Method B is a redundant test, resulting in no additional safety or information beyond that gained from Method A.
10.14359/51689470
Results Per Page 5 10 15 20 25 50 100