International Concrete Abstracts Portal

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

Showing 1-5 of 544 Abstracts search results

Document: 

26-046

Date: 

September 23, 2026

Author(s):

Yitao Zhou, Guibin Wang, Huandui Liu, Yu Song, Mida Fang

Publication:

Materials Journal

Abstract:

Lined rock cavern (LRC) hydrogen storage requires concrete linings with high tensile ductility and stable crack-control capacity under circumferential tension. Although polyvinyl alcohol (PVA) fibers exhibit high tensile strength and good alkali resistance, their hydrophilicity may induce a loose interfacial transition zone (ITZ), thereby limiting effective fiber bridging. This study proposes a cost-effective fiber-surface modification strategy by combining polydopamine (PDA) with nano-CaCO3. Unlike conventional single surface-treatment methods, the proposed system simultaneously introduces a protective slip-buffering layer and a mineral particle-enhanced ITZ. The PDA layer serves as an adhesive carrier and a protective slip layer, reducing direct abrasion between the fiber and cementitious matrix during interfacial sliding. Meanwhile, nano-CaCO3 particles anchored on the PDA layer increase fiber-surface roughness and provide nucleation/filling sites for hydration products, promoting ITZ densification and stronger mechanical interlocking. SEM and FTIR results confirm the successful formation of the PDA/nano-CaCO3 coating, while tensile tests and DIC analysis show that the modified fibers promote stable strain hardening and more uniform multiple cracking. Numerical simulation further indicates that the improved HDC lining can disperse localized cracking and alleviate damage transfer to the surrounding rock. These results demonstrate that the PDA-assisted nano-CaCO3 modification provides an effective physicochemical route for enhancing PVA fiber-reinforced HDC used in LRC hydrogen storage.

DOI:

10.14359/51752078


Document: 

25-287

Date: 

September 1, 2026

Author(s):

U. Neupane, F. Niyonyungu, R. D. Lequesne, A. Lepage, and D. Darwin

Publication:

Structural Journal

Volume:

123

Issue:

5

Abstract:

Six large-scale reinforced concrete column-foundation connections, designed to represent interior connections of a continuous foundation slab, were subjected to reversed-cyclic displacements to investigate the effects of foundation longitudinal reinforcement ratio (ρ), foundation thickness (h), column hooked-bar embedment length (ℓe), and foundation shear reinforcement on connection deformation capacity. The specimens were designed to be nominally similar to a specimen from an earlier study, except for the variables of interest. In all specimens, strength was limited by column bar yielding and deformation capacity was governed by concrete breakout, even though the embedment length was adequate to yield the column bars. ACI CODE-318-25 was published late in the course of this study, so specimens did not satisfy ACI CODE‑318-25 Section 25.4.11 requirements for anchorage of bar groups in tension. Test results indicate that improved drift ratio capacity can be achieved by either: a) delaying column-bar yield strain penetration into the foundation with increased foundation longitudinal reinforcement ratio ρ or column longitudinal bar embedment length ℓe; or b) increasing concrete breakout resistance with longer ℓe or foundation shear reinforcement that has a shear strength exceeding the shear demand associated with 40% of the transfer moment based on the eccentric shear stress model assuming vc = 0. The concept of transfer width (based on ℓe instead of h) is useful for designing foundations to resist column moment transfer, but foundation flexural reinforcement for moment transfer should be placed near the top of the foundation instead of divided between the top and bottom mats. Column longitudinal bars should be extended to the bottom mat of foundation reinforcement because terminating the bars near foundation middepth resulted in earlier breakout and lower deformation capacity.

DOI:

10.14359/51750613


Document: 

25-315

Date: 

September 1, 2026

Author(s):

H. Zhang, X. Cao, Z. Hao, D. Wang, Z. Zhang, H. Zhao, Y. Fan, and J. Wang

Publication:

Structural Journal

Volume:

123

Issue:

5

Abstract:

Conventional anchor-bolt-confined flexible formwork concrete walls for gob-side entry retaining have clear inherent technical limitations, including incompatible deformation between steel anchors and concrete, low construction efficiency, and grout leakage. However, existing studies have not fundamentally solved the core mechanical problem of confinement efficiency loss caused by deformation mismatch, nor have they established a complete theoretical design framework for new high-compatibility confined systems, which severely limits their application in complex underground conditions. This study develops an innovative prefabricated stirrup-confined flexible formwork concrete system, identifies two primary surrounding rock fracture modes through theoretical analysis, establishes corresponding mechanical models for support design, and verifies the system through laboratory tests and full-scale field trials. The high-strength fiber stirrups achieve tensile strength equivalent to that of deformed steel bars, with an elongation of ≤6%, significantly improving deformation compatibility with concrete. Field results show that the optimized system delivers excellent surrounding rock control, with a maximum roof subsidence of 65 mm, wall displacement of 30 mm, and floor heave of 35 mm. This study provides a validated design framework for high-efficiency confined concrete underground support structures.

DOI:

10.14359/51751739


Document: 

25-348

Date: 

September 1, 2026

Author(s):

Mostafa Osman Serry, Mohamed Salah Eldin Darwish, and Ezzeldin Yazeed Sayed-Ahmed

Publication:

Structural Journal

Volume:

123

Issue:

5

Abstract:

Prestressed concrete (PC) enables slender, economical, and durable structures, with post-tensioned (PT) precast girders widely used in bridge construction. Accurate design requires precise prediction of prestress losses, among which friction losses arising from duct curvature, wobble, and anchorage slip are most significant. Existing codes employ simplified exponential models, yet notable discrepancies persist between predicted and actual field values. This study presents full-scale experimental testing on PT precast girders used in Egypt’s Light Railway Transit (LRT) project. Prestress forces were measured using strain gauges to evaluate friction losses along tendon profiles. Results revealed that measured losses consistently exceeded code-based predictions, highlighting the influence of stress level and nonlinear variation along the tendon, factors often ignored by current provisions. Regression analysis yielded refined exponential models with improved accuracy and strong agreement with observations. The proposed refinements enhance predictive reliability and provide a foundation for updating design codes toward safer, more realistic PT concrete structures.

DOI:

10.14359/51750685


Document: 

26-041

Date: 

August 26, 2026

Author(s):

Ibrahim A. Abdelwahed and Ehab F. El-Salakawy

Publication:

Structural Journal

Abstract:

Openings in the vicinity of reinforced concrete (RC) slab-column connections exacerbate the susceptibility of flat plates to punching shear failure. Using Glass Fiber-Reinforced Polymer (GFRP) as flexural reinforcement may reduce punching resistance due to its low modulus of elasticity. However, GFRP headed-end bars offer greater stiffness, ease of installation, reliable anchorage, and less reinforcement congestion than bent bars. This study presents the results of five full-scale slab-column edge connections. The test parameters are the type of reinforcement (GFRP and steel), anchorage (bent and headed end), and the presence of slab openings in the vicinity of the column. All specimens exhibited sudden punching shear failure. Slabs reinforced with GFRP headed-end bars showed no evidence of anchorage failure. Openings significantly reduced punching capacity, with a similar percentage for both steel- and GFRP-RC slabs. Moreover, Canadian Standards and American codes highly underestimated the capacity of the specimens.

DOI:

10.14359/51752023