ACI Global Home Middle East Region Portal Western Europe Region Portal
Email Address is required Invalid Email Address
In today’s market, it is imperative to be knowledgeable and have an edge over the competition. ACI members have it…they are engaged, informed, and stay up to date by taking advantage of benefits that ACI membership provides them.
Read more about membership
Learn More
Become an ACI Member
Topics In Concrete
Home > Publications > International Concrete Abstracts Portal
The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.
Showing 1-5 of 64 Abstracts search results
Document:
CI4610Bischoff
Date:
October 1, 2024
Author(s):
Peter H. Bischoff
Publication:
Concrete International
Volume:
46
Issue:
10
Abstract:
The article discusses slender wall design at service loads with the new expression for the effective moment of inertia introduced into ACI 318-19(22), which now uses a reduced cracking moment for computing deflection. A recommendation is also made to provide a limiting condition for the axial wall load to avoid erroneous calculation of the factored moment by direct calculation.
CI4602Nagele
February 1, 2024
Trent Nagele, John Lawson, and Jeff Griffin
2
Slender concrete walls for tilt-up construction are typically designed following the alternative slender wall provisions in ACI 318. Wall designers however may implement different theoretical approaches with the belief that their efforts will increase accuracy and efficiency. Unfortunately, these usually run counter to the observed experimental behavior and can lead to significantly unconservative wall designs.
CI4002Q&A2
February 1, 2018
40
I’m designing a structure that will be exposed to chlorides in soil, so I’m reviewing the requirements listed in Table 19.3.2.1 —Requirements for concrete by exposure class, in ACI 318- 14.1 The chloride concentration in the soil is lower than the concentration in seawater, so can I specify concrete with a strength value between 2500 and 5000 psi (17.2 and 34.5 MPa), based on C1 and C2 exposure classes, respectively? Does ACI provide recommendations on cleaning concrete slabs during tilt-up construction?
CI3801TCAAwards
January 1, 2016
38
1
CI3701TCAAwards
January 1, 2015
37
The Tilt-Up Concrete Association (TCA) announced the recipients of the 24th Annual Tilt-Up Achievement Awards.
Results Per Page 5 10 15 20 25 50 100