Variable Cylindrical Concrete Confined by Carbon Fiber- Reinforced Polymer under Axial Compression

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

  


Title: Variable Cylindrical Concrete Confined by Carbon Fiber- Reinforced Polymer under Axial Compression

Author(s): Yail J. Kim and Aliasghar Hassani

Publication: Structural Journal

Volume: 120

Issue: 4

Appears on pages(s): 89-102

Keywords: carbon fiber-reinforced polymer (CFRP); confinement; rehabilitation; strengthening; variable cross sections.

DOI: 10.14359/51737340

Date: 7/1/2023

Abstract:
This paper presents the axial behavior of cylindrical concrete with variable cross sections confined by carbon fiber-reinforced polymer (CFRP) sheets. The test specimens are classified into three conformational categories: right angles (Type 1), truncated cones (Types 2 and 3), and barrels (Types 4 and 5), which are subjected to a preload level of 0%fc′, 30%fc′, and 60%fc′ (fc′ is the compressive strength of plain concrete) for the representation of existing damage in core concrete prior to wrapping with CFRP. The average capacity of the confined concrete in Type 1 is 106% higher than that of its unconfined counterpart. With an increase in the taper angle, the axial resistance of Types 2 and 3 is improved due to the enlarged base areas; however, the expanded bellies along the height of Types 4 and 5 lower the capacity by reducing the confining pressure of the CFRP sheets. Although the adverse effects of the preloading are evident in the context of reserved reliability and damage evolution, the validity of the confinement system is preserved from a strengthening standpoint. The geometric attributes dominate the load-displacement relationships, post-peak deformations, energy dissipation, and failure characteristics of the specimens. Analytical modeling clarifies that, compared with other parameters, the thickness of CFRP is the salient factor influencing the confining pressure of the system. According to the principle of energy conservation, a simplified design proposal is suggested to calculate the strength of the confined nonprismatic concrete.

Related References:

1. Groper, M., and Kenig, M. J., “Inelastic Buckling of Nonprismatic Columns,” Journal of Engineering Mechanics, ASCE, V. 113, No. 8, Aug. 1987, pp. 1233-1239. doi: 10.1061/(ASCE)0733-9399(1987)113:8(1233)

2. AASHTO, “Guide Specifications for Design of Bonded FRP Systems for Repair and Strengthening of Concrete Bridge Elements,” American Association of State Highway and Transportation Officials, Washington, DC, 2012.

3. ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19) (Reapproved 2022),” American Concrete Institute, Farmington Hills, MI, 2019, 624 pp.

4. Manzelli, A. A., and Harik, I. E., “Prismatic and Nonprismatic Slender Columns and Bridge Piers,” Journal of Structural Engineering, ASCE, V. 119, No. 4, Apr. 1993, pp. 1133-1149. doi: 10.1061/(ASCE)0733-9445(1993)119:4(1133)

5. Goel, M. D.; Bedon, C.; Singh, A.; Khatri, A. P.; and Gupta, L. M., “An Abridged Review of Buckling Analysis of Compression Members in Construction,” Buildings, V. 11, No. 5, May 2021, Article No. 211. doi: 10.3390/buildings11050211

6. Sayed, A. M.; Rashwan, M. M.; and Helmy, M. E., “Experimental Behavior of Cracked Reinforced Concrete Columns Strengthened with Reinforced Concrete Jacketing,” Materials, V. 13, No. 12, June 2020, Article No. 2832. doi: 10.3390/ma13122832

7. Villar-Salinas, S.; Guzmán, A.; and Carrillo, J., “Performance Evaluation of Structures with Reinforced Concrete Columns Retrofitted with Steel Jacketing,” Journal of Building Engineering, V. 33, Jan. 2021, Article No. 101510. doi: 10.1016/j.jobe.2020.101510

8. ACI Committee 440, “Report on Fiber-Reinforced Polymer (FRP) Reinforcement for Concrete Structures (ACI 440R-07),” American Concrete Institute, Farmington Hills, MI, 2007, 100 pp.

9. Al-Saadi, N. T. K.; Mohammed, A.; Al-Mahaidi, R.; and Sanjayan, J., “A State-of-the-Art Review: Near-Surface Mounted FRP Composites for Reinforced Concrete Structures,” Construction and Building Materials, V. 209, June 2019, pp. 748-769. doi: 10.1016/j.conbuildmat.2019.03.121

10. Gkournelos, P. D.; Triantafillou, T. C.; and Bournas, D. A., “Seismic Upgrading of Existing Reinforced Concrete Buildings: A State-of-the-Art Review,” Engineering Structures, V. 240, Aug. 2021, Article No. 112273. doi: 10.1016/j.engstruct.2021.112273

11. ACI Committee 440, “Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures (ACI 440.2R-17),” American Concrete Institute, Farmington Hills, MI, 2017, 112 pp.

12. Si Youcef, Y.; Amziane, S.; and Chemrouk, M., “CFRP Confinement Effectiveness on the Behavior of Reinforced Concrete Columns with Respect to Buckling Instability,” Construction and Building Materials, V. 81, Apr. 2015, pp. 81-92. doi: 10.1016/j.conbuildmat.2015.02.006

13. Zhou, J.; Tian, Y.; Bi, F.; and Zhao, X., “Size Effect on Strength of Reinforced Concrete Cylinders Confined by Carbon Fiber-Reinforced Polymer and Transverse Stirrup Reinforcement,” ACI Structural Journal, V. 118, No. 2, Mar. 2021, pp. 263-272.

14. Karam, G. N., and Tabbara, M. R., “Localization and Confinement Efficiency in Carbon Fiber-Reinforced Plastic-Confined Materials,” ACI Structural Journal, V. 117, No. 6, Nov. 2020, pp. 7-15.

15. Ahmad, A.; Khan, Q. U. Z.; and Raza, A., “Reliability Analysis of Strength Models for CFRP-Confined Concrete Cylinders,” Composite Structures, V. 244, July 2020, Article No. 112312. doi: 10.1016/j.compstruct.2020.112312

16. Kashi, A.; Ramezanianpour, A. A.; Moodi, F.; and Malekitabar, H., “Effect of Aggressive Marine Environment on Strain Efficiency Factor of FRP-Confined Concrete,” Construction and Building Materials, V. 222, Oct. 2019, pp. 882-891. doi: 10.1016/j.conbuildmat.2019.07.055

17. Wu, Y.-F., and Cao, Y., “Energy Balance Method for Modeling Ultimate Strain of Confined Concrete,” ACI Structural Journal, V. 114, No. 2, Mar.-Apr. 2017, pp. 373-381. doi: 10.14359/51689429

18. Jiang, K.; Han, Q.; Bai, Y.; and Du, X., “Data-Driven Ultimate Conditions Prediction and Stress-Strain Model for FRP-Confined Concrete,” Composite Structures, V. 242, June 2020, Article No. 112094. doi: 10.1016/j.compstruct.2020.112094

19. Teng, J. G.; Jiang, T.; Lam, L.; and Luo, Y. Z., “Refinement of a Design-Oriented Stress–Strain Model for FRP-Confined Concrete,” Journal of Composites for Construction, ASCE, V. 13, No. 4, Aug. 2009, pp. 269-278. doi: 10.1061/(ASCE)CC.1943-5614.0000012

20. Rocca, S.; Galati, N.; and Nanni, A., “Review of Design Guidelines for FRP Confinement of Reinforced Concrete Columns of Noncircular Cross Sections,” Journal of Composites for Construction, ASCE, V. 12, No. 1, Feb. 2008, pp. 80-92. doi: 10.1061/(ASCE)1090-0268(2008)12:1(80)

21. Guler, S., and Ashour, A., “Review of Current Design Guidelines for Circular FRP-Wrapped Plain Concrete Cylinders,” Journal of Composites for Construction, ASCE, V. 20, No. 2, Apr. 2016, p. 04015057. doi: 10.1061/(ASCE)CC.1943-5614.0000619

22. Raza, S.; Khan, M. K. I.; Menegon, S. J.; Tsang, H.-H.; and Wilson, J. L., “Strengthening and Repair of Reinforced Concrete Columns by Jacketing: State-of-the-Art Review,” Sustainability, V. 11, No. 11, June 2019, Article No. 3208. doi: 10.3390/su11113208

23. Teng, J. G., and Lam, L., “Behavior and Modeling of FRP-Confined Concrete: A State-of-the-Art Review,” International Symposium on Confined Concrete, SP-238, Y. Xiao, S. Kunnath, and W. Yi, eds., American Concrete Institute, Farmington Hills, MI, 2006, pp. 327-346.

24. ASTM C39/C39M-18, “Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens,” ASTM International, West Conshohocken, PA, 2018, 8 pp.

25. Ramaswamy, A.; Chachithanantham, S.; and Arumugam, S., “Performance of BFRP Retrofitted RCC Piles Subjected to Axial Loads,” Advances in Materials Science and Engineering, V. 2014, 2014, Article No. 323909. doi: 10.1155/2014/323909

26. Wang, H.; Li, C.; Tu, J.; and Li, D., “Dynamic Tensile Test of Mass Concrete with Shapai Dam Cores,” Materials and Structures, V. 50, No. 1, Feb. 2017, Article No. 44. doi: 10.1617/s11527-016-0901-x

27. Wang, J.; Lu, S.; and Yang, J., “Behavior of Eccentrically Loaded Rectangular RC Columns Wrapped with CFRP Jackets under Different Preloading Levels,” Journal of Building Engineering, V. 34, Feb. 2021, Article No. 101943. doi: 10.1016/j.jobe.2020.101943

28. Ugural, A. C., and Fenster, S. K., Advanced Strength and Applied Elasticity, third edition, Prentice Hall, Hoboken, NJ, 1995.

29. Nowak, A. S., and Collins, K. R., Reliability of Structures, second edition, CRC Press, Boca Raton, FL, 2013.