Moment Transfer at Column-Foundation Connections: Physical Tests

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

  


Title: Moment Transfer at Column-Foundation Connections: Physical Tests

Author(s): Benjamin L. Worsfold, Jack P. Moehle, and John F. Silva

Publication: Structural Journal

Volume: 119

Issue: 5

Appears on pages(s): 95-110

Keywords:

DOI: 10.14359/51734799

Date: 9/1/2022

Abstract:
Steel and precast columns are commonly designed to transfer moment loads to concrete foundations through cast-in-place headed anchors. In design office practice in the United States, connection strength has been evaluated considering mechanisms emphasizing joint shear, strut-and-tie modeling, and anchoring to concrete. For any given connection, the strengths calculated with these three methods can differ by a wide margin. The application of these methods, including possible enhancements that improve strength estimates, is described. Laboratory tests were performed to provide benchmark physical data to determine the applicability of various design methods. The test specimens consisted of full-scale interior steel-column-to-concrete-foundation connections located away from foundation edges, with details typical of current construction practice on the West Coast of the United States. Strength in both tests was governed by concrete breakout failure. Strategically placed reinforcement increased the strength and displacement capacity of anchored connections governed by breakout. Design recommendations are provided.

Related References:

ACI Committee 318, 2019, “Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19),” American Concrete Institute, Farmington Hills, MI, 624 pp.

Bažant, Z. P., 2000, “Size Effect,” International Journal of Solids and Structures, V. 37, No. 1-2, Jan., pp. 69-80. doi: Elsevier Science Ltd.10.1016/S0020-7683(99)00077-3

Caltrans, 2016, “Memo to Designers (MTD) 20-7: Seismic Design of Slab Bridges,” California Department of Transportation, Sacramento, CA, Apr., 12 pp.

Eligehausen, R., and Balogh, T., 1995, “Behavior of Fasteners Loaded in Tension in Cracked Reinforced Concrete,” ACI Structural Journal, V. 92, No. 3, May-June, pp. 365-379.

Eligehausen, R.; Bouška, P.; Červenka, V.; and Pukl, R., 1992, “Size Effect of the Concrete Cone Failure Load of Anchor Bolts,” Fracture Mechanics of Concrete Structures, Z. P. Bažant, ed., Taylor & Francis Group, London, UK, pp. 517-525.

Eligehausen, R.; Mallée, R.; and Silva, J. F., 2006, Anchorage in Concrete Construction, Ernst & Sohn, Berlin, Germany, 391 pp.

EN 1992-4:2018, 2018, “Eurocode 2 – Design of Concrete Structures – Part 4: Design of Fastenings for Use in Concrete,” European Committee for Standardization, Brussels, Belgium, 129 pp.

Fisher, J. M., and Kloiber, L. A., 2006, “Steel Design Guide 1: Base Plate and Anchor Rod Design,” second edition, American Institute of Steel Construction (AISC), 63 pp.

Fuchs, W.; Eligehausen, R.; and Breen, J. E., 1995, “Concrete Capacity Design (CCD) Approach for Fastening to Concrete,” ACI Structural Journal, V. 92, No. 1, Jan.-Feb., pp. 73-94.

Herzog, M., 2015, “Beitrag zur Vereinheitlichung der Bemessung im Stahlbetonbau und in der Befestigungstechnik (Contribution to the Standardization of Design in Reinforced Concrete Construction and Fastening Technology),” PhD dissertation, University of Stuttgart, Stuttgart, BW, Germany, 457 pp. (in German)

Joint ACI-ASCE Committee 352, 2002, “Recommendations for Design of Beam-Column Connections in Monolithic Reinforced Concrete Structures (ACI 352R-02) (Reapproved 2010),” American Concrete Institute, Farmington Hills, MI, 38 pp.

Kupfer, H.; Münger, F.; Kunz, J.; and Jähring, A., 2003, “Hauptaufsätze – Nachträglich verankerte gerade Bewehrungsstäbe bei Rahmenknoten (Anchorage of Post Installed Straight Bars for Frame Node Connections),” Bauingenieur, V. 78, No. 1, pp. 24-37. (in German)

Mahrenholtz, C.; Akguzel, U.; Eligehausen, R.; and Pampanin, S., 2014, “New Design Methodology for Seismic Column-to-Foundation Anchorage Connections,” ACI Structural Journal, V. 111, No. 5, Sept.-Oct., pp. 1179-1189.

Nilforoush, R.; Nilsson, M.; and Elfgren, L., 2018, “Experimental Evaluation of Influence of Member Thickness, Anchor-Head Size, and Orthogonal Surface Reinforcement on the Tensile Capacity of Headed Anchors in Uncracked Concrete,” Journal of Structural Engineering, ASCE, V. 144, No. 4, Apr., p. 04018012. doi: 10.1061/(ASCE)ST.1943-541X.0001976

Nilforoush, R.; Nilsson, M.; Elfgren, L.; Ožbolt, J.; Hofmann, J.; and Eligehausen, R., 2017, “Influence of Surface Reinforcement, Member Thickness, and Cracked Concrete on Tensile Capacity of Anchor Bolts,” ACI Structural Journal, V. 114, No. 6, Nov.-Dec., pp. 1543-1556. doi: 10.14359/51689505

Ožbolt, J.; Elighausen, R.; and Reinhardt, H. W., 1999, “Size Effect on the Concrete Cone Pull-Out Load,” International Journal of Fracture, V. 95, No. 1-4, Jan., Article No. 391. doi: 10.1023/A:1018685225459

Papadopoulos, V.; Murcia-Delso, J.; and Shing, P. B., 2018, “Development of Headed Bars in Slab-Column Joints of Reinforced Concrete Slab Bridges,” ACI Structural Journal, V. 115, No. 5, Sept., pp. 1393-1406. doi: 10.14359/51702247

RILEM TC 50, 1985, “FMC 1: Determination of the Fracture Energy of Mortar and Concrete by Means of Three-Point Bend Tests on Notched Beams,” Materials and Structures, V. 18, No. 4, July, pp. 287-290.

RILEM TC 89, 1994, “FMC 2: Size-Effect Method for Determining Fracture Energy and Process Zone Size of Concrete,” RILEM Technical Recommendations for the Testing and Use of Construction Materials, E & FN Spon, London, UK, pp. 102-106.

Sharma, A.; Eligehausen, R.; and Asmus, J., 2017a, “Comprehensive Analytical Model for Anchorages with Supplementary Reinforcement,” Proceedings, 3rd International Symposium on Connections between Steel and Concrete (ConSC 2017), Sept. 27-29, Stuttgart, Germany, pp. 253-265

Sharma, A.; Eligehausen, R.; and Asmus, J., 2017b, “Comprehensive Experimental Investigations on Anchorages with Supplementary Reinforcement,” Proceedings, 3rd International Symposium on Connections between Steel and Concrete (ConSC 2017), Sept. 27-29, Stuttgart, Germany, pp. 242-252

Tanaka, R., and Oba, K., 2001, “Experimental Study on Seismic Performance of Beam Members Connected with Post-Installed Anchors,” International Symposium on Connections between Steel and Concrete, R. Eligehausen, ed., Stuttgart, Germany, RILEM Publications SARL, pp. 576-585.

Worsfold, B., and Moehle, J., 2019, “Laboratory Tests of Column-Foundation Moment Transfer Connections with Headed Anchors,” UCB/SEMM-2019/01, Structural Engineering, Mechanics and Materials (SEMM) Report, University of California, Berkeley, Berkeley, CA, 171 pp.

Worsfold, B., and Moehle, J., 2022, “Laboratory Tests of Column-Foundation Moment Transfer Connections with Shear Reinforcement,” UCB/SEMM-2022/01, Structural Engineering, Mechanics and Materials (SEMM) Report, University of California, Berkeley, Berkeley, CA, 243 pp.


ALSO AVAILABLE IN:

Electronic Structural Journal



  

Edit Module Settings to define Page Content Reviewer