Increase in Coating Thickness of Epoxy-Coated Steel Reinforcing Bars for Concrete Deck Replacement

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

  


Title: Increase in Coating Thickness of Epoxy-Coated Steel Reinforcing Bars for Concrete Deck Replacement

Author(s): Rachel E. Henkhaus, Sandra Villamizar, and Julio A. Ramirez

Publication: Materials Journal

Volume: 117

Issue: 5

Appears on pages(s): 67-79

Keywords: bond strength; deformed reinforcement; development length; epoxy-coating thickness; lap connections; normalweight concrete

DOI: 10.14359/51727018

Date: 9/1/2020

Abstract:
The allowable range of epoxy coating thickness specified by ASTM A775/A775M is 175 to 400 μm (7 to 16 mils). This study investigates the impact on structural performance of increasing the upper limit of epoxy coating thickness to 460 μm (18 mils) with respect to deflections, cracking, and bond strength of tension splices. Twenty beam specimens containing single splices as well as splices of bundled bars were tested to failure. The experimental parameters were ranges of epoxy coating thicknesses (300 to 380 μm [12 to 15 mils] and 460 to 530 μm [18 to 21 mils]) and bar sizes No. 16 and 29 [No. 5 and 9]). Test results confirmed the applicability of current code requirements for development and splice length of epoxy-coated bars in tension in ACI 318-14 and AASHTO LFRD 2014, including bars in bundles, up to a coating thickness not to exceed 460 μm (18 mils).

Related References:

1. Samples, L. M., and Ramirez, J. A., “Methods of Corrosion Protection and Durability of Concrete Bridge Decks Reinforced with Epoxy-Coated Bars-Phase 1,” Report No. FHWA-IN-JTRP-98-15, Joint Transportation Research Program, West Lafayette, IN, 1999.

2. Johnston, D. W., and Zia, P., “Bond Characteristics of Epoxy Coated Reinforcing Bars,” Report No. FHWA-NC-82-002, Federal Highway Administration, Washington, DC, 1982.

3. Treece, R. A., and Jirsa, J. O., “Bond Strength of Epoxy-Coated Reinforcing Bars,” ACI Materials Journal, V. 86, No. 2, Mar.-Apr. 1989, pp. 167-174.

4. Choi, O. C.; Hadje-Ghaffari, H.; Darwin, D.; and McCabe, S. L., “Bond of Epoxy-Coated Reinforcement: Bar Parameters,” ACI Materials Journal, V. 88, No. 2, Mar.-Apr. 1991, pp. 207-217.

5. Cleary, D. B., and Ramirez, J. A., “Epoxy-Coated Reinforcement under Repeated Loading,” ACI Structural Journal, V. 90, No. 4, July-Aug. 1993, pp. 451-458.

6. Appelhans, M., and Ramirez, J. A., “Performance-Related Specifications for Concrete Bridge Superstructures, Volume 4: Bond of Epoxy-Coated Bars with Thicker Coatings,” Report No. FHWA-IN JTRP-2001-8-IV, Joint Transportation Research Program, West Lafayette, IN, 2002.

7. Miller, G. G.; Kepler, J. L.; and Darwin, D., “Effect of Epoxy Coating Thickness on Bond Strength of Reinforcing Bars,” ACI Structural Journal, V. 100, No. 3, May-June 2003, pp. 314-320.

8. ASTM A944-99, “Standard Test Method for Comparing Bond Strength of Steel Reinforcing Bars to Concrete Using Beam-End Specimens,” ASTM International, West Conshohocken, PA, 1999.

9. ASTM A775/A775M-01, “Standard Specification for Epoxy-Coated Steel Reinforcing Bars,” ASTM International, West Conshohocken, PA, 2001.

10. Jirsa, J. O.; Chen, W.; Grant, D. B.; and Elizondo, R., “Development of Bundled Reinforcing Steel,” Report No. 1363-2F, U.S. Department of Transportation, Federal Highway Administration, University of Texas at Austin, Austin, TX, 1995.

11. Hester, C. J.; Salamizavaregh, S.; Darwin, D.; and McCabe, S. L., “Bond of Epoxy-Coated Reinforcement: Splices,” ACI Structural Journal, V. 90, No. 1, Jan.-Feb. 1993, pp. 89-102.

12. ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14),” American Concrete Institute, Farmington Hills, MI, 2014, 520 pp.

13. AASHTO LRFD, “Load and Resistance Factor Design Bridge Design Specifications,” American Association of State Highway and Transportation Officials, Washington, DC, 2014.

14. Ramirez, J. A., and Henkhaus, R. E., “Deck Replacement—Use of Extra Coating Thickness Epoxy-Coated Bars,” Report No. FHWA-IN-JTRP-2007-8, Joint Transportation Research Program, West Lafayette, IN, 2008.

15. Henkhaus, R. E., “Effect of Epoxy Thickness on Bond between Concrete and Coated Reinforcement,” PhD thesis, Purdue University, West Lafayette, IN, 2009.

16. Samples, L. M., and Ramirez, J. A., “Field Investigations of Concrete Bridge Decks in Indiana: Part 1: New Construction & Initial Field Investigation of Existing Bridge Decks,” Concrete International, V. 22, No. 2, Feb. 2000, pp. 53-56.

17. Samples, L. M., and Ramirez, J. A., “Field Investigations of Concrete Bridge Decks in Indiana: Part 2: Detailed Investigation of Existing Decks,” Concrete International, V. 22, No. 3, Mar. 2000, pp. 59-63.

18. ASTM C39/C39M-04, “Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens,” ASTM International, West Conshohocken, PA, 2004, 6 pp.

19. ASTM C78-02, “Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading),” ASTM International, West Conshohocken, PA, 2002, 3 pp.

20. ASTM A370-05, “Standard Test Methods and Definitions for Mechanical Testing of Steel Products,” ASTM International, West Conshohocken, PA, 2005, 47 pp.

21. Cleary, D. B., and Ramirez, J. A., “Bond Strength of Epoxy-Coated Reinforcement,” ACI Materials Journal, V. 88, No. 2, Mar.-Apr. 1991, pp. 146-149.

22. Hasan, H. O.; Cleary, D. B.; and Ramirez, J. A., “Performance of Concrete Bridge Decks and Slabs Reinforced with Epoxy-Coated Steel under Repeated Loading,” ACI Structural Journal, V. 93, No. 4, July-Aug. 1996, pp. 397-403.

23. Darwin, D.; Tholen, M. L.; Idun, E. K.; and Zuo, J., “Splice Strength of High Relative Rib Area Reinforcing Bars,” ACI Structural Journal, V. 93, No. 1, Jan.-Feb. 1996, pp. 95-107.