Evaluation of Autoclaved Aerated Concrete Floor Diaphragms Subjected to In-Plane Loads

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

  


Title: Evaluation of Autoclaved Aerated Concrete Floor Diaphragms Subjected to In-Plane Loads

Author(s): Vanessa L. Storlie, Cody K. Parker, and Jennifer E. Tanner

Publication: Structural Journal

Volume: 117

Issue: 3

Appears on pages(s): 199-206

Keywords: autoclaved aerated concrete (AAC); floor diaphragm; strutand- tie; testing

DOI: 10.14359/51724554

Date: 5/1/2020

Abstract:
Autoclaved aerated concrete (AAC) is a cellular concrete with consistent material properties. AAC structures have many advantages including ease of construction, low density, and high fire and thermal resistance. In this study, a suite of 14 scaled floor diaphragms were tested to determine physical behavior of the system subjected to either monotonic and cyclic loads. Next, a simple strut-and-tie model (STM) was used as a mechanism to predict the strength of floor diaphragms subject to in-plane lateral loads. Testing validated that although the model violates the minimum angle of 25 degrees, individual panel movement and nodal confinement permit sufficient rotation. Test results indicate that the STM provides conservative predictions for the strength of floor diaphragms.

Related References:

ACI Committee 318, 2014, “Building Code Requirements for Structural Concrete and Commentary (ACI 318-14),” American Concrete Institute, Farmington Hills, MI, 520 pp.

ACI Committee 526, 2019, “Guide for Design and Construction with Autoclaved Aerated Concrete Panels (ACI 526R-19)” American Concrete Institute, Farmington Hills, MI, 82 pp.

Ali, M. A., and White, R. N., 2001, “Consideration of Compression Stress Bulging and Strut Degradation in Truss Modeling of Ductile and Brittle Corbels,” Engineering Structures, V. 23, No. 3, pp. 240-249. doi: 10.1016/S0141-0296(00)00040-7

Argudo, J., 2003, “Evaluation and Synthesis of Experi¬mental Data for Autoclaved Aerated Concrete,” master’s thesis, Department of Civil Engineering, The University of Texas at Austin, Austin, TX, 297 pp.

ASTM C1692, 2011, “Standard Practice for Construction and Testing of Autoclaved Aerated Concrete (AAC) Masonry,” ASTM International, West Conshohocken, PA.

ASTM C476, 2002, “Standard Specifications for Grout for Masonry,” ASTM International, West Conshohocken, PA.

Chen, B. S.; Hagenberger, M. J.; and Breen, J. E., 2002, “Evaluation of Strut-and-Tie Modeling Applied to Dapped Beam with Opening,” ACI Structural Journal, V. 99, No. 4, July-Aug., pp. 454-450.

Chen, Y.; Peng, M.; Zhang, Y.; and Liu, Y., 2013, “Mechanical Properties of Autoclaved Aerated Concrete with Different Densities,” Advances in Civil Engineering Materials, ASTM, V. 2, No. 1, pp. 441-456.

Fouad, F. H., and Dembowski, J., 2005, “Mechanical Properties of Plain AAC Material,” Autoclaved Aerated Concrete—Properties and Structural Design, SP-226, C. Shi and F. H. Fouad, eds., American Concrete Institute, Farmington Hills, MI, pp. 1-16.

Griebenow, G.; Koch, R.; Sitka, R.; and Volkel, G., 1989, “Loadbearing Floor Plates of Autoclaved Aerated Concrete Components,” Concrete Precasting Plant and Technology, V. 55, No. 6, pp. 56-66.

Halici, O. F.; Ugurlu, K.; Demir, C.; Comert, M.; and Ilki, A., 2018, “Evaluation of Diaphragm Conditions in AAC Floor Structures with RC Beams,” Bulletin of Earthquake Engineering, V. 16, No. 12, p. 61316162 doi: 10.1007/s10518-018-0434-5

Matamoros, A. B., and Wong, K. H., 2003, “Design of Simply Supported Deep Beams Using Strut-and-Tie Models,” ACI Structural Journal, V. 100, No. 6, Nov.-Dec., pp. 704-712.

Matthys, J. H., and Barnett, R. E., 2004, “New Masonry Products for the US Designer Emerges – Autoclaved Aerated Concrete,” Proceedings of the 2004 Structures Congress, American Society of Civil Engineers, Nashville, TN, pp. 1001-1111.

Maxwell, B. S., and Breen, J. E., 2000, “Experimental Evaluation of a Strut-and-Tie Model Applied to Deep Beam with Opening,” ACI Structural Journal, V. 97, No. 1, Jan.-Feb., pp. 142-148.

Park, J., and Kuchma, D., 2007, “Strut-and-Tie Model Analysis for Strength Prediction of Deep Beams,” ACI Structural Journal, V. 104, No. 6, Nov.-Dec., pp. 657-666.

Parker, C., 2005, “Evaluation of a Strut-and-Tie Model to Design Autoclaved Aerated Concrete Floor Diaphragms to Resist Lateral Load,” MS thesis, University of Wyoming, Laramie, WY, 184 pp.

Parker C. K.; Tanner J. E.; and Varela J. L., 2008, “Evaluation of ASTM Methods to Determine Splitting Tensile Strength in Concrete, Masonry, and Autoclaved Aerated Concrete,” ASTM Journal of Testing and Evaluation, V. 4, No. 2, 12 pp.

Polla, M., 1992, “A Study of Nodal Regions in Strut and Tie Models,” master’s thesis, University of Toronto, Toronto, ON, Canada, 130 pp.

Porter, M. L., and Sabri, A. A., 1990, “Plank Diaphragm Characteristics,” U.S.-Japan Coordinated Program for Masonry Building Research, No. 5.1-1, 226 pp.

Quintero-Febres, C. G., Parra-Montesinos, G. P. and Wight, J. K., 2006, “Strength of Struts in Deep Concrete Members Designed using the Strut-and-Tie Method,” ACI Structural Journal, V. 103, No. 4, July-Aug., pp. 577-586..

Schlaich, J., and Schäfer, K., 1991, “Design and Detailing of Structural Concrete Using Strut-and-Tie Models,” Structural Engineering, V. 69, No. 6, pp. 113-125.

Short, A., and Kinniburgh, W., 1961, “The Structural Use of Aerated Concrete,” The Structural Engineer, V. 39, pp. 1-16.

Singh, P. K., and Chaturvedi, H. S., 1997, “Joint Reinforcement Strut-and-Tie Model,” Concrete International, V. 19, No. 8, Aug., pp. 74-77.

Storlie, V. L., 2009, “Behavior of Autoclaved Aerated Concrete Floor Diaphragms Subject to In-Plane Reverse Cyclic Loading,” MS thesis, University of Wyoming, Laramie, WY, 154 pp.

Tan, K. H.; Tong, K.; and Tang, C. Y., 2001, “Direct Strut-and-Tie Model for Prestressed Deep Beams,” Journal of Structural Engi­­neering, ASCE, V. 127, No. 9, pp. 1076-1084. doi: 10.1061/(ASCE)0733-9445(2001)127:9(1076)

Tanner, J. E.; Varela, J. L.; and Klingner, R. E., 2005a, “Design and Seismic Testing of Two-Story, Full-Scale Autoclaved Aerated Concrete Assemblage Specimen,” ACI Structural Journal, V. 102, No. 1, Jan.-Feb., pp. 114-119.

Tanner J. E.; Varela J. L.; Brightman M. J.; Cancino U.; and Klingner R. E., 2005b, “Seismic Testing of Autoclaved Aerated Concrete (AAC) Shear Walls: A Complete Review,” ACI Structural Journal, V. 102, No. 3, May-June, pp. 374-382. doi: 10.14359/14408.

Tanner, J. E.; Varela, J. L.; and Klingner, R. E., 2011, “Validation of Material Properties and Masonry Standards Joint Committee Code Provisions for Autoclaved Aerated Concrete Masonry,” Proceedings, 11th North American Masonry Conference, Minneapolis, MN.

Yardim, Y.; Waleed, A. M. T.; Jaafar, M. S.; and Laseima, S., 2013, “AAC-Concrete Light Weight Precast Composite Floor Slab,” Construction and Building Materials, V. 40, pp. 405-410. doi: 10.1016/j.conbuildmat.2012.10.011


ALSO AVAILABLE IN:

Electronic Structural Journal



  

Edit Module Settings to define Page Content Reviewer