Abstract:
This paper presents an experimental study characterizing the
chemicoelectric response of concrete bonded with carbon fiber-reinforced polymer (CFRP) sheets in a corrosive environment. A rapid chloride permeability test is conducted with concrete specimens having variable CFRP coverage ratios from 0% (uncovered) to 100% (fully covered) according to ASTM C1202. Test results substantiate that CFRP sheets are an effective medium impeding the ingress of chlorides into CFRP-strengthened concrete structures, thereby alleviating the likelihood of corrosion damage. CFRP-bonding causes a decrease in electric current and chloride diffusivity. Microscopic images showing residual sodium chloride crystals accumulated on the surface of the tested specimens corroborate the decreasing rate of the electric current. The resistivity of the concrete and the transport rate of chlorides are controlled by the CFRP coverage ratio influencing an electrolytic process. Due to the distribution of electric charges, the conduction of the CFRP-bonded concrete alters from non-steady state to steady state with time due to the distribution of electric charges. An analytical expression is proposed for modeling chloride diffusion in the vicinity of CFRP-bonded regions.
Related References:
1. FHWA, “National Bridge Inventory: Bridges by Structure Type,” Federal Highway Administration, Washington, DC, 2015.
2. Bentz, D. P., “A Virtual Rapid Chloride Permeability Test,” Cement and Concrete Composites, V. 29, No. 10, 2007, pp. 723-731. doi: 10.1016/j.cemconcomp.2007.06.006
3. Mohamed, A. R.; El-Nadoury, W. W.; and Ayyob, M. T., “Generalized Chloride Permeability Test for Blended and Nonblended Concrete,” ACI Materials Journal, V. 111, No. 3, May-June 2014, pp. 327-333. doi: 10.14359/51686578
4. Kong, L., and Ge, Y., “Mechanism Study of Effect of Coarse Aggregate Size on Permeability of Concrete,” ACI Materials Journal, V. 112, No. 6, Nov.-Dec. 2015, pp. 767-774. doi: 10.14359/51688181
5. Liu, Y.; Presuel-Moreno, F. J.; and Paredes, M. A., “Determination of Chloride Diffusion Coefficients in Concrete by Electrical Resistivity Method,” ACI Materials Journal, V. 112, No. 5, Sept.-Oct. 2015, pp. 631-640. doi: 10.14359/51687777
6. ACI Committee 440, “Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures (ACI 440.2R-08),” American Concrete Institute, Farmington Hills, MI, 2008, 76 pp.
7. ACI Committee 440, “Report on Fiber-Reinforced Polymer (FRP) Reinforcement for Concrete Structures (ACI 440R-07),” American Concrete Institute, Farmington Hills, MI, 2007, 100 pp.
8. Wootton, I. A.; Spainhour, L. K.; and Yazdani, N., “Corrosion of Steel Reinforcement in Carbon Fiber-Reinforced Polymer Wrapped Concrete Cylinders,” Journal of Composites for Construction, ASCE, V. 7, No. 4, 2003, pp. 339-347. doi: 10.1061/(ASCE)1090-0268(2003)7:4(339)
9. Nossoni, G.; Harichandran, R. S.; and Baiyasi, M. I., “Rate of Reinforcement Corrosion and Stress Concentration in Concrete Columns Repaired with Bonded and Unbonded FRP Wraps,” Journal of Composites for Construction, ASCE, V. 19, No. 5, 2015, p. 04014080 doi: 10.1061/(ASCE)CC.1943-5614.0000547
10. ASTM C1202-12, “Standard Test Method for Electrical Indication of Concrete’s Ability to Resist Chloride Ion Penetration,” ASTM International, West Conshohocken, PA, 2012, 8 pp.
11. CEB, “Diagnosis and Assessment of Concrete Structures: State-of-the-Art Report (CEB-192),” Bulletin D’Information, Case Postale 88, Lausanne, Switzerland, 1989.
12. Berke, N., and Hicks, M., “Estimating the Life Cycle of Reinforced Concrete Decks and Marine Piles Using Laboratory Diffusion and Corrosion Data,” ASTM STP 1137: Corrosion Forms and Control of Infrastructure, ASTM International, West Conshohocken, PA, 1992.
13. Streicher, P., and Alexander, M., “A Chloride Conduction Test for Concrete,” Cement and Concrete Research, V. 25, No. 6, 1995, pp. 1284-1294. doi: 10.1016/0008-8846(95)00121-R
14. Neville, A. M., Properties of Concrete, Prentice Hall, London, UK, 1995.
15. The Concrete Society, “Technical Report 32: Analysis of Hardened Concrete,” Surrey, UK, 2014.
16. Chatterji, S., “Transportation of Ions through Cement-Based Materials: Part I—Fundamental Equations and Basic Measurement Techniques,” Cement and Concrete Research, V. 24, No. 5, 1994, pp. 907-912. doi: 10.1016/0008-8846(94)90010-8
17. Atadero, R. A., and Karbhari, V. M., “Calibration of Resistance Factors for Reliability-Based Design of Externally-Bonded FRP Composites,” Composites. Part B, Engineering, V. 39, No. 4, 2008, pp. 665-679. doi: 10.1016/j.compositesb.2007.06.004
18. Daniel, W. W., Applied Nonparametric Statistics, second edition, Cengage Learning, Boston, MA, 2000.
19. Thoft-Christensen, P.; Jensen, F. M.; Midleton, C. R.; and Blackmore, A., “Assessment of the Reliability of Concrete Slab Bridges,” 7th IFIP WG 7.5 Working Conference, Boulder, CO, 1996, pp. 1-8.
20. Stewart, M. G., and Rosowsky, D. V., “Time-Dependent Reliability of Deteriorating Reinforced Concrete Bridge Decks,” Structural Safety, V. 20, No. 1, 1998, pp. 91-109. doi: 10.1016/S0167-4730(97)00021-0
21. Mehta, P. K., and Monteiro, P. J. M., Concrete: Microstructure, Properties, and Materials, McGraw-Hill, New York, 2014.
22. Bisby, L. A., “Fire Behaviour of Fibre-Reinforced Polymer (FRP) Reinforced or Confined Concrete,” PhD thesis, Queen’s University, Kingston, ON, Canada, 2003.