International Concrete Abstracts Portal

  


Title: Repairs to Paulina Street Parking Structure

Author(s): John F. Vincent and Peter R. Kolf

Publication: Concrete International

Volume: 16

Issue: 3

Appears on pages(s): 39-41

Keywords: camber; concrete materials; concrete repairs; post-tensioning; reinforcing steels; Construction

DOI:

Date: 3/1/1994

Abstract:
The Paulina Street Parking Structure is a 17-year-old concrete facility comprised of post-tensioned slabs and support beams, and conventionally reinforced columns. Typical slabs are continuous over six spans, while beams are continuous over two or three spans. Post-tensioning system consists of unbonded, monostrand tendons. Post-tensioned members also contain bonded, conventional reinforcement at locations of maximum flexural stress.




  