Title: Loss of Air Content in Pumped Concrete

Author(s): James Yingling, Gary M. Mullings, and Richard D. Gaynor

Publication: Concrete International

Volume: 14

Issue: 10

Appears on pages(s): 57-61

Keywords: admixtures; air entrainment; bubbles; pumped concrete; sampling; slump; tests; Structural Research

DOI:

Date: 10/1/1992

Abstract:
Describes an investigation of the phenomenon of loss of entrained air in pumped concrete. Conclusions and recommendations include: 1) With long vertically downward boom or pipe sections, half the air can be lost; 2) Do some sampling at the pump discharge; 3) If air is lost, fix the problem. Don't try to compensate by mixing high air content concrete in the truck.




  