Title:
Report of the Committee on Reinforced Concrete and Building Laws
Author(s):
ACI Committee on Committee on Reinforced Concrete and Building Laws
Publication:
Journal Proceedings
Volume:
8
Issue:
3
Appears on pages(s):
61-157
Keywords:
none
DOI:
10.14359/16152
Date:
3/1/1912
Abstract:
In accordance with the program of tests on completed structures presented to the Association at the last convention, four tests have been made, two of them on standard forms of reinforced concrete floors in which the concrete slab is supported by one or more intermediate beams which in turn are framed into or supported by girders carrying the load to the columns. Of the other two tests one is on the girderless or flat slab floor, and the other on a combination of tile and concrete floor, in which the reinforcement is placed in two directions.