Title: Moment Transfer at Interior Slab-Column Connections

Author(s): Scott D. B. Alexander and Sidney H. Simmonds

Publication: Structural Journal

Volume: 100

Issue: 2

Appears on pages(s): 197-202

Keywords: column; reinforced concrete; slab

DOI: 10.14359/12483

Date: 3/1/2003

Abstract:
Under the American design standard, ACI 318, the strength of slab-column connections is assessed using an interaction equation that includes contributions from both shear and unbalanced moment. Based on a reexamination of tests reported by Hanson and Hanson, the unbalanced moment at interior connections is shown to contribute far less to transverse shear than is assumed in design. A simple limit analysis is presented. This analysis is more consistent with observed behavior and accepted material limits and better predicts the test results.