Nonlinear Modeling Parameters and Acceptance Criteria for Interior Slab-Column Connections

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

  


Title: Nonlinear Modeling Parameters and Acceptance Criteria for Interior Slab-Column Connections

Author(s): Yan Zhou and Mary Beth D. Hueste

Publication: Structural Journal

Volume: 119

Issue: 1

Appears on pages(s): 145-154

Keywords: acceptance criteria; ACI 369.1; ASCE 41; nonlinear modeling parameters; performance-based design; post-tensioned; reinforced concrete; seismic evaluation; slab-column connections

DOI: 10.14359/51733009

Date: 1/1/2022

Abstract:
This paper reviews the lateral deformation capacity of reinforced concrete and post-tensioned slab-column (SC) connections and the corresponding ACI 369.1-17 and ASCE 41-17 modeling parameters for nonlinear analysis. An updated database of experiments for interior SC connection tests without shear reinforcement under combined gravity and lateral load effects has been documented. Proposed drift-based nonlinear modeling parameters are derived considering a detailed review of the backbone response of each individual SC connection specimen. Expressions for limiting drift ratios as a function of the gravity shear ratio are developed to describe the backbone response for nonlinear analysis, along with the limiting drifts for performance-based seismic evaluation. The recommended drift-based nonlinear modeling parameters and acceptance criteria are compared with the current provisions in ASCE 41-17.

Related References:

ACI-ASCE Committee 352, 2011, “Guide for Design of Slab-Column Connections in Monolithic Concrete Structures (ACI 352.1R-11),” American Concrete Institute, Farmington Hills, MI, 28 pp.

ACI Committee 318, 2019, “Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19),” American Concrete Institute, Farmington Hills, MI, 624 pp.

ACI Committee 369, 2017, “Standard Requirements for Seismic Evaluation and Retrofit of Existing Concrete Buildings (ACI 369.1-17) and Commentary (ACI 369.1R-17),” American Concrete Institute, Farmington Hills, MI, 110 pp.

ASCE/SEI 41-17, 2017, “Seismic Evaluation and Retrofit of Existing Buildings,” American Society of Civil Engineers, Reston, VA, 550 pp.

Choi, M. S.; Cho, I. J.; Han, B. S.; Ahn, J. M.; and Shin, S. W., 2007, “Experimental Study of Interior Slab-Column Connections Subjected to Vertical Shear and Cyclic Moment Transfer,” Key Engineering Materials, V. 348-349, Sept., pp. 641-644. doi: 10.4028/www.scientific.net/KEM.348-349.641

Drakatos, I.-S.; Muttoni, A.; and Beyer, K., 2016, “Internal Slab-Column Connections under Monotonic and Cyclic Imposed Rotations,” Engineering Structures, V. 123, Sept., pp. 501-516. doi: 10.1016/j.engstruct.2016.05.038

Elwood, K. J.; Matamoros, A. B.; Wallace, J. W.; Lehman, D. E.; Heintz, J. A.; Mitchell, A. D.; Moore, M. A.; Valley, M. T.; Lowes, L. N.; Comartin, C. D.; and Moehle, J. P., 2007, “Update to ASCE/SEI 41 Concrete Provisions,” Earthquake Spectra, V. 23, No. 3, Aug., pp. 493-523. doi: 10.1193/1.2757714

FEMA 356, 2000, “Prestandard and Commentary for the Seismic Rehabilitation of Buildings (FEMA 356),” Federal Emergency Management Agency, Washington, DC, Nov., 518 pp.

Ghannoum, W. M., and Matamoros, A. B., 2014, “Nonlinear Modeling Parameters and Acceptance Criteria for Concrete Columns,” Seismic Assessment of Existing Reinforced Concrete Buildings, SP-297, K. J. Elwood, J. Dragovich, and I. Kim, eds., American Concrete Institute, Farmington Hills, MI, Mar., pp. 1.1-1.24.

Hueste, M. B. D.; Browning, J.; Lepage, A.; and Wallace, J. W., 2007, “Seismic Design Criteria for Slab-Column Connections,” ACI Structural Journal, V. 104, No. 4, July-Aug., pp. 448-458.

Hueste, M. B. D., and Wight, J. K., 1999, “Nonlinear Punching Shear Failure Model for Interior Slab-Column Connections,” Journal of Structural Engineering, ASCE, V. 125, No. 9, Sept., pp. 997-1008. doi: 10.1061/(ASCE)0733-9445(1999)125:9(997)

Hufnagel, A. C.; Heo, Y. A.; and Kang, T. H.-K., 2014, “Modeling Parameters for Reinforced Concrete Slab-Column Connections,” Seismic Assessment of Existing Reinforced Concrete Buildings, SP-297, K. J. Elwood, J. Dragovich, and I. Kim, eds., American Concrete Institute, Farmington Hills, MI, Mar., pp. 5.1-5.16.

Kang, T. H.-K., and Wallace, J. W., 2006, “Punching of Reinforced and Post-Tensioned Concrete Slab-Column Connections,” ACI Structural Journal, V. 103, No. 4, July-Aug., pp. 531-540.

Kang, T. H.-K.; Robertson, I. N.; Hawkins, N. M.; and LaFave, J. M., 2008, “Recommendations for Design of Post-Tensioned Slab-Column Connections Subjected to Lateral Loading,” PTI JOURNAL, V. 6, No. 1, Feb., pp. 45-59.

Luo, Y. H., and Durrani, A. J., 1995, “Equivalent Beam Model for Flat-Slab Buildings—Part I: Interior Connections,” ACI Structural Journal, V. 92, No. 1, Jan.-Feb., pp. 115-124.

Megally, S., and Ghali, A., 2000, “Punching Shear Design of Earthquake-Resistant Slab-Column Connections,” ACI Structural Journal, V. 97, No. 5, Sept.-Oct., pp. 720-730.

Muttoni, A., 2008, “Punching Shear Strength of Reinforced Concrete Slabs without Transverse Reinforcement,” ACI Structural Journal, V. 105, No. 4, July-Aug., pp. 440-450.

Pan, A. P., and Moehle, J. P., 1988, “Reinforced Concrete Flat Plates under Lateral Loading: An Experimental Study Including Biaxial Effects,” Report to the National Science Foundation, Report No. UCB/EERC-88/16, University of California, Berkeley, Berkeley, CA, Oct., 286 pp.

Pan, A., and Moehle, J. P., 1989, “Lateral Displacement Ductility of Reinforced Concrete Flat Plates,” ACI Structural Journal, V. 86, No. 3, May-June, pp. 250-258.

Rha, C.; Kang, T. H.-K.; Shin, M.; and Yoon, J. B., 2014, “Gravity and Lateral Load-Carrying Capacities of Reinforced Concrete Flat Plate Systems,” ACI Structural Journal, V. 111, No. 4, July-Aug., pp. 753-764. doi: 10.14359/51686731

Robertson, I., and Johnson, G., 2006, “Cyclic Lateral Loading of Nonductile Slab-Column Connections,” ACI Structural Journal, V. 103, No. 3, May-June, pp. 356-364.

Zhou, Y., 2019, “Seismic Performance Assessment and Nonlinear Modeling Parameters for Slab-Column Connections,” PhD dissertation, Texas A&M University, College Station, TX, Aug., 265 pp.

Zhou, Y., and Hueste, M. B. D., 2017, “Review of Test Data for Interior Slab-Column Connections with Moment Transfer,” ACI/fib International Symposium on Punching Shear in Structural Concrete Slabs: Honoring Neil M. Hawkins, SP-315, C. E. Ospina, D. Mitchell, and A. Muttoni, eds., American Concrete Institute, Farmington Hills, MI, Apr., pp. 141-166.

Zhou, Y., and Hueste, M. D., 2018, “Evaluation of Nonlinear Modeling Parameters for Reinforced Concrete Slab-Column Connections,” Proceedings, Eleventh U.S. National Conference on Earthquake Engineering, Los Angeles, CA, June, 11 pp.