Effect of Stirrups on Lateral Cyclic Behavior of Interior Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab- Column Connections

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

  


Title: Effect of Stirrups on Lateral Cyclic Behavior of Interior Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab- Column Connections

Author(s): Mohamed Eladawy, Mohamed Hassan, Brahim Benmokrane, and Amir Fam

Publication: Structural Journal

Volume: 117

Issue: 5

Appears on pages(s): 161-175

Keywords: concrete slab-column connection; drift-ductility index; energy dissipation; glass fiber-reinforced polymer reinforcement; interstory- drift capacity; punching shear; reversed lateral cyclic loading; shear reinforcement

DOI: 10.14359/51724671

Date: 9/1/2020

Abstract:
Providing shear reinforcement around slab-column connections in flat-plate structures located in seismic zones has proved to be effective in enhancing the punching shear performance of slabs. It results in increased punching shear strength, lateral-drift capacity, and ductility factor, while reducing connection stiffness deterioration. This paper presents the first-ever experimental investigation on five full-scale concrete slab-column connections reinforced with glass fiber-reinforced-polymer (GFRP) bars and stirrups. Each slab measured 2500 x 2500 mm with a thickness of 200 mm, and 300 mm square column extending 700 mm above and below the slab surfaces. All specimens were tested to failure under the combination of gravity and lateral reversed cyclic loading. The experimental study aimed to evaluate the effects of stirrups type (closed and spiral), stirrup extension, and gravity-load intensity on the seismic behavior of the connections. The test results showed that using GFRP stirrups around the slab-column connection significantly enhanced the seismic performance of the connection. The slabs with GFRP stirrups exhibited punching-shear failure with a gradual decrease in lateral load and maintained their integrity. Slabs reinforced with GFRP stirrups achieved lateral inter-storydrift capacity exceeding 2.5%, satisfying the limits in CSA A23.3 and ACI 421.2R. Moreover, all shear-reinforced slabs demonstrated high lateral-ductility indexes which are higher than the minimum ductility factor of 1.2 for steel-RC slab-column connections. Additionally, slabs with GFRP stirrups displayed an excellent ability to dissipate energy during high lateral-drift levels.

Related References:

ACI Committee 318, 2014, “Building Code Requirements for Structural Concrete (ACI 318-14),” American Concrete Institute, Farmington Hills, MI, 520 pp.

ACI Committee 421, 2010, “Guide to Seismic Design of Punching Shear Reinforcement in Flat Plates (ACI 421.2R-2010),” American Concrete Institute, Farmington Hills, MI, 30 pp.

ACI Committee 440, 2004, “Guide Test Methods for Fiber-Reinforced Polymers (FRPs) for Reinforcing or Strengthening Concrete Structures (ACI 440.3R-04).” American Concrete Institute, Farmington Hills, MI, 40 pp.

ACI Committee 440, 2015, “Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars (ACI 440.1R-15),” American Concrete Institute, Farmington Hills, MI, 88 pp.

ASTM D7205/D7205M-11, 2011, “Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix Composite Bars,” ASTM International, West Conshohocken, PA, 12 pp.

Benmokrane, B.; Ahmed, E.; Dulude, C.; and Boucher, E., 2012, “Design, Construction, and Monitoring of the First Worldwide Two Way Flat Slab Parking Garage Reinforced with GFRP Bars.” Proceedings of the 6th International Conference on FRP Composites in Civil Engineering, 8 pp.

Bu, W., and Polak, M. A., 2009, “Seismic Retrofit of Reinforced Concrete Slab-column Connections using Shear Bolts,” ACI Structural Journal, V. 106, No. 4, July-Aug., pp. 514-522.

Canadian Standards Association (CSA), 2007, “Parking Structures (CAN/CSA 413-07),” Rexdale, ON, Canada, 240 pp.

Canadian Standards Association (CSA), 2012, “Design and Construction of Building Structures with Fiber Reinforced Polymers (CAN/CSA S806-12),” Rexdale, ON, Canada, 198 pp.

Canadian Standards Association (CSA), 2014, “Canadian Highway Bridge Design Code (CAN/CSA S6-14),” Rexdale, ON, Canada, 798 pp.

Canadian Standards Association (CSA), 2014, “Design of Concrete Structures for Buildings (CSA-A23.3 M-14),” Rexdale, ON, Canada, 240 pp.

Canadian Standards Association (CSA), 2015, “Specification for Fiber-Reinforced Polymers (CAN/CSA S807-15),” Rexdale, ON, Canada, 27 pp.

Dulude, C.; Hassan, M.; Ahmed, E. A.; and Benmokrane, B., 2013, “Punching Shear Behaviour of Two-Way Flat Concrete Slabs Reinforced with Glass Fiber-Reinforced Polymer Bars,” ACI Structural Journal, V. 110, No. 5, Sept.-Oct., pp. 723-734.

El-Gendy, M.G. and El-Salakawy, E., 2018, “Lateral Displacement Deformability of GFRP-RC Slab-Column Edge Connections,” The 13th International Symposium on Fiber-Reinforced Polymer Reinforcement for Concrete Structures, SP-327, American Concrete Institute, Farmington Hills, MI, pp. 52.1-52.20.

Emam, M.; Marzouk, H.; and Hilal, S., 1997, “Seismic Response of Slab-Column Connections Constructed With High-Strength Concrete,” ACI Structural Journal, V. 94, No. 2, Mar.-Apr., pp. 197-205.

Gouda, A., and El-Salakawy, E., 2016, “Behavior of GFRP-RC Interior Slab-Column Connections with Shear Studs and High-Moment Transfer,” Journal of American Society of Civil Engineers, ASCE, V. 20, No. 4, p. 04016005. doi: 10.1061/(ASCE)CC.1943-5614.0000663

Hassan, M.; Ahmed, E.; and Benmokrane, B., 2015, “Punching Shear Behavior of Two-Way Slabs Reinforced with FRP Shear Reinforcement,” Journal of Composites for Construction, ASCE, V. 19, No. 1, Feb., p. 04014030. doi: 10.1061/(ASCE)CC.1943-5614.0000493

Hassan, M.; Ahmed, E. A.; and Benmokrane, B., 2013, “Punching-Shear Strength of GFRP-Reinforced Concrete Flat Slabs,” Canadian Journal of Civil Engineering, V. 40, No. 10, Apr., pp. 951-960. doi: 10.1139/cjce-2012-0177

Hussein, A., and El-Salakawy, E., 2018, “Punching Shear Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab-Column Interior Connections,” ACI Structural Journal, V. 115, No. 4, July, pp. 1075-1088.

Kang, T. H.-K.; Lee, J. D.; Lee, B. S.; and Bum, M. J., 2017, “Punching and Lateral Cyclic Behavior of Slab-Column Connections with Shear Bands,” ACI Structural Journal, V. 114, No. 5, Sept.-Oct., pp. 1075-1086.

Megally, S., 1998, “Punching Shear Resistance of Concrete Slabs to Gravity and Earthquake Forces.” PhD thesis, Department of Civil Engineering, University of Calgary, Calgary, AB, Canada, 504 pp.

NBCC, 2015, “National Building Code of Canada,” National Research Council of Canada, Ottawa, ON, Canada, 1222 pp.

Pan, A., and Moehle, J. P., 1989, "Lateral Displacement Ductility of Reinforced Concrete Flat Plates,” ACI Structural Journal, V. 86, No. 3, May-June, pp. 250-258.

Park, R., 1989, “Evaluation of Ductility of Structures and Structural Assemblages from Laboratory Testing,” Bulletin of the New Zealand Society for Earthquake Engineering, V. 22, No. 3, pp. 155-166. doi: 10.5459/bnzsee.22.3.155-166

Pillai, S. U.; Kirk, W.; and Scavuzzo, L., 1982, “Shear Reinforcement at Slab-Column Connections in a Reinforced Concrete Flat Plate Structure,” ACI Structural Journal, V. 79, No. 1, Jan-Feb., pp. 36-42.

Robertson, I. N.; Kawai, T.; Lee, J.; and Enomoto, B., 2002, “Cyclic Testing of Slab-Column Connections with Shear Reinforcement,” ACI Structural Journal, V. 99, No. 5, Sept.-Oct., pp. 605-613.


ALSO AVAILABLE IN:

Electronic Structural Journal



  

Edit Module Settings to define Page Content Reviewer