Title:
Effect of Low-Temperature Installation on Adhesive Anchors
Author(s):
Werner Fuchs, Jan Hofmann, and Gerrit Hülder
Publication:
Concrete International
Volume:
38
Issue:
1
Appears on pages(s):
48-56
Keywords:
curing, conversion, load, stiffness
DOI:
Date:
1/1/2016
Abstract:
Until recently, the behavior of adhesive anchors installed in cold concrete components was inadequately investigated. The article presents background information on the load-bearing behavior of adhesive anchors installed at low temperatures, describes corresponding tests, and reports test results. These results indicate that the behavior of low-temperature installation of adhesive anchor products is sufficiently considered in the product prequalification provisions now specified in the United States.