International Concrete Abstracts Portal

Showing 1-5 of 452 Abstracts search results

Document: 

CI4611Tepke

Date: 

November 1, 2024

Author(s):

David G. Tepke and Stephen S. Szoke

Publication:

Concrete International

Volume:

46

Issue:

11

Abstract:

This article discusses development of code requirements from an idea into an application and then to refinement toward industry advancement. It provides an overview of the process, including common scenarios related to the development of new and modification of existing industry standards.


Document: 

CI4607Klinger

Date: 

July 1, 2024

Author(s):

James E. Klinger, Eamonn F. Connolly, Charles D. Charlson, Oscar R. Antommattei, and Bruce A. Suprenant

Publication:

Concrete International

Volume:

46

Issue:

7

Abstract:

Various codes, specifications, and reports provide different requirements/recommendations for anchor bolt (rod) installation in foundations. The article discusses the issues related to these requirements/recommendations and encourages designers to add 2 in. (50 mm) to the calculated design embedment length and to specify the elevation of the top of the anchor bolt.


Document: 

SP-360_01

Date: 

March 1, 2024

Author(s):

Junrui Zhang, Enrique del Rey Castillo, Ravi Kanitkar, Aniket D Borwankar, and Ramprasath R

Publication:

Symposium Papers

Volume:

360

Abstract:

A systematic literature review was conducted on pure tension strengthening of concrete structures using fiber-reinforced polymer (FRP), specifically for larger FRP tie applications. This work yielded a dataset of 1,627 direct tension tests, and highlighted the limitation of existing studies on studying thick and long FRP ties, which are typical in real construction scenarios. To overcome this shortcoming, 51 single lap shear tests were conducted on thicker and longer FRP ties, with the dimensions being 0.5 to 6 mm [0.02 to 0.24 in.] thickness, and 300 to 1,524 mm [12 to 60 in.] long. The critical parameters under consideration were concrete compressive strength, FRP thickness, and bond length. The findings demonstrate that thicker and therefore stiffer FRP ties have higher debond force capacity, while longer ties exhibit greater post-elastic deformation capacity but do not affect the debond force capacity. Concrete had a limited effect on either debond force or deformation capacity. A strength model is proposed for FRP systems under axial pure tension, which aligns well with both the published and tested results. This paper focuses on the development of design guidelines and codes to predict the debond strain for EB-FRP systems incorporating thicker and longer FRP ties, aiming to enhance the applicability of FRP to real-world construction scenarios.

DOI:

10.14359/51740613


Document: 

SP-360_45

Date: 

March 1, 2024

Author(s):

C. Barris, F. Ceroni, A. Perez Caldentey

Publication:

Symposium Papers

Volume:

360

Abstract:

Serviceability checks in Reinforced Concrete (RC) elements involves the verification of crack width mainly aimed to limit the exposure of the steel reinforcement to corrosion and chemical attack and, thus, improve durability. Classical approaches for assessing the crack width in RC elements provide the calculation of two terms: 1) the average crack spacing, and 2) the average difference between the strain in the steel reinforcement and in the concrete in tension referred to the average crack spacing. A similar approach can be assumed valid also for RC elements strengthened with externally bonded Fiber Reinforced Polymer (FRP) materials, taking into account the additional tension stiffening effect provided by the external reinforcement.

This paper presents the comparisons of some existing code formulations for predicting crack spacing and crack width in RC elements with the experimental results of a database collected by the Authors and concerning tests on RC beams and ties externally bonded with different types and configurations of FRP materials. The paper is mainly aimed to check the reliability of the existing equations provided by codes in order to address the future assessment of reliable design provisions for cracking verifications in RC elements strengthened with FRP materials. The comparisons have evidenced, indeed, some useful issues for the design provisions: 1) larger scatter in the predictions of crack width than in crack spacing and, in particular, for ties, 2) limited effect of shrinkage on crack width, 3) necessity of taking into account the external reinforcement in crack spacing formulations, 4) good reliability of mechanical models for calculating cracks width.

DOI:

10.14359/51740657


Document: 

SP-360_30

Date: 

March 1, 2024

Author(s):

Yasser M. Selmy and Ehab F. El-Salakawy

Publication:

Symposium Papers

Volume:

360

Abstract:

The seismic performance of reinforced concrete (RC) bridge columns subjected to multidirectional ground motions is a critical issue, as these columns can experience axial compression, bending, and torsional loading. Moreover, steel corrosion is a significant concern in existing bridges, leading to deficiencies in steel-RC structural members. The use of glass fiber-reinforced polymer (GFRP) reinforcement has been established as a practical and effective solution to mitigate the corrosion-related issues associated with traditional steel reinforcement in concrete structures. However, the dissimilar mechanical properties of GFRP and steel have raised apprehensions regarding its feasibility in seismic-resistant structures. The current study involves conducting an experimental investigation to assess the feasibility of utilizing GFRP reinforcement as a substitute for conventional steel reinforcement in circular RC bridge columns subjected to cyclic lateral loading, which induces shear, bending, and torsion. One column was reinforced with GFRP bars and stirrups, while the other column, served as a control and was reinforced with conventional steel reinforcement. The aim of this investigation was to analyze the lateral displacement deformability and energy dissipation characteristics of the GFRP-RC column. The results showed that GFRP-RC column exhibited stable post-peak behavior and high levels of deformability under the applied combined loading. Additionally, with a torsion-to-bending moment ratio of 0.2, both columns reached similar lateral load and torsional moment capacities and were able to attain lateral-drift capacities exceeding the minimum requirements of North American design codes and guidelines.

DOI:

10.14359/51740642


12345...>>

Results Per Page 





ABOUT THE INTERNATIONAL CONCRETE ABSTRACTS PORTAL

  • The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

Edit Module Settings to define Page Content Reviewer