ACI CODE-550.5M-18: Code Requirements for the Design of Precast Concrete Diaphragms for Earthquake Motions (Metric)

Currency Display

Your Price:$ 104.50 USD

Member Price: $ 64.00 USD

Save $ 40.50 USD, Become a Member

Choose Product Language

Choose Product Units


Choose Product Format


Notes/Preview

Preview

Description

This standard describes code requirements for the design of precast concrete diaphragms subject to earthquake motions where used under the design provisions of ASCE/SEI 7-16 Section 12.10.3 and ACI 318M. The response of precast concrete diaphragms under earthquake motions depends primarily on the strength, stiffness, and deformation capacities of the connectors and the reinforcement at joints between the precast concrete members. The seismic forces specified in ASCE/SEI 7 for the design of precast concrete diaphragms, their chords, and collectors in structures assigned to Seismic Design Category (SDC) C, D, E, or F are tied to force reduction factors specified in ASCE/SEI 7-16 Chapter 12, and to the shear overstrength provided by the connections and the reinforcement at joints specified in ASCE/SEI 7-16 Chapter 14. The shear overstrength depends on the design methodology, elastic or ductile, used for the diaphragm and targets elastic response for the maximum considered earthquake for shear connections regardless of the design option selected. The design option that can be used depends on the assigned design category and on the span and aspect ratio of the diaphragm. The selection of the design option is associated with minimum requirements for the tensile deformation capacity of the connections and the reinforcement at joints.

Keywords:

connections; diaphragms; earthquake-resistant structures; precast concrete; seismic design.

 

Document Details

Author: ACI Committee 550

Publication Year: 2018

Pages: 214

ISBN: 9781641950275

Categories: Codes, Precast Concrete

Formats: PDF

Table of Contents

CHAPTER 1—GENERAL

1.1—Introduction

1.2—Scope

1.3—Structural drawings

1.4—Units

CHAPTER 2—NOTATION AND DEFINITIONS

2.1—Notation

2.2—Definitions

CHAPTER 3—REFERENCED STANDARDS

CHAPTER 4—GENERAL CONSIDERATIONS

4.1—General design considerations

4.2—Materials

4.3—Minimum thickness

4.4—Tolerances

CHAPTER 5—DESIGN FORCES, SEISMIC DEMAND LEVELS, AND ANALYSIS

5.1—General

5.2—Diaphragm seismic design force

5.3—Diaphragm seismic demand level

5.4—Diaphragm nominal shear strength

5.5—Diaphragm modeling and analysis

CHAPTER 6—DIAPHRAGM DESIGN OPTIONS

6.1—General

6.2—Elastic design option

6.3—Basic design option

6.4—Reduced design option

CHAPTER 7—DIAPHRAGM CONNECTIONS AND REINFORCEMENT AT JOINTS

7.1—General

7.2—Connection classifications

7.3—Deformed bar reinforcement

7.4—Special inspection

R8—COMMENTARY REFERENCES AND ACRONYMS

R8.1—References

R8.2—Acronyms

ERRATA INFO

Any applicable errata are included with individual documents at the time of purchase. Errata are not included for collections or sets of documents such as the ACI Collection. For a listing of and access to all product errata, visit the Errata page.

Return/Exchange Policy

Printed / Hard Copy Products: The full and complete returned product will be accepted if returned within 60 days of receipt and in salable condition. A 20% service charge applies. Return shipping fees are the customer’s responsibility.

Electronic /Downloaded Products & Online Learning Courses: These items are not eligible for return.

Subscriptions These items are not eligible for return.

Exchanges: Contact ACI’s Customer Services Department for options (+1.248.848.3800 – ACICustomerService@concrete.org).