Effects of Type of Bar Lap Splice on Reinforced Concrete Columns Subjected to Cyclic Loading

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

  


Title: Effects of Type of Bar Lap Splice on Reinforced Concrete Columns Subjected to Cyclic Loading

Author(s): Chul-Goo Kim, Hong-Gun Park, and Tae-Sung Eom

Publication: Structural Journal

Volume: 116

Issue: 2

Appears on pages(s): 183-194

Keywords: cyclic test; lap splice; offset bar splice; reinforced concrete column; seismic performance; splice detail; splice length

DOI: 10.14359/51711142

Date: 3/1/2019

Abstract:
In this study, tension lap splices of longitudinal bars on columns subjected to cyclic lateral loading and low axial load (N = 0.15 to 0.185Agfc′) were investigated. Cyclic lateral loading tests were performed for eight columns with different lengths and methods of lap splices. The test results showed that the flexural strength and ductility of columns were significantly affected by the lap splice offset methods, as well as by the lap splice length and the moment gradient. When the lower bars were offset inside the column for the lap splice, the ductility of the column was the greatest but the flexural strength was less than the nominal flexural strength without bar offsets. On the other hand, when the upper bars were offset or when the upper and lower bars were lap-spliced side by side without offset bends, the flexural strength of the columns satisfied the nominal strength but the ductility decreased. Based on the test results, design considerations for the lap splices are recommended.

Related References:

1. ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14),” American Concrete Institute, Farmington Hills, MI, 2014, 519 pp.

2. ACI Committee 315, “Details and Detailing of Concrete Reinforcement (ACI 315-99),” American Concrete Institute, Farmington Hills, MI, 1999, pp. 1-44.

3. Eurocode 2, “Design of Concrete Structures: Part 1-1: General Rules and Rules for Buildings,” British Standards Institution, London, UK, 2004, pp. 132-143.

4. Kim, C. G.; Park, H. G.; and Eom, T. S., “Seismic Performance of Reinforced Concrete Columns with Lap Splices in Plastic Hinge Region,” ACI Structural Journal, V. 115, No. 1, Jan. 2018, pp. 235-245. doi: 10.14359/51701109

5. Lynn, A. C.; Moehle, J. P.; Mahin, S. A.; and Holmes, W. T., “Seismic Evaluation of Existing Reinforced Concrete Building Columns,” Earthquake Spectra, V. 12, No. 4, 1996, pp. 715-739. doi: 10.1193/1.1585907

6. Melek, M., and Wallace, J. W., “Cyclic Behavior of Columns with Short Lap Splices,” ACI Structural Journal, V. 101, No. 6, Nov.-Dec. 2004, pp. 802-811.

7. Boyes, A.; Bull, D. K.; and Pampanin, S., “Seismic Performance of Concrete Columns with Inadequate Transverse Reinforcement,” University of Canterbury, Christchurch, New Zealand, 2008, 12 pp.

8. Aboutaha, R. S.; Engelhardt, M. D.; Jirsa, J. O.; and Kreger, M. E., “Experimental Investigation of Seismic Repair of Lap Splice Failures in Damaged Concrete Columns,” ACI Structural Journal, V. 96, No. 2, Mar.-Apr. 1999, pp. 297-306.

9. Haroun, M. A., and Elsanadedy, H. M., “Fiber-Reinforced Plastic Jackets for Ductility Enhancement of Reinforced Concrete Bridge Columns with Poor Lap-Splice Detailing,” Journal of Bridge Engineering, ASCE, V. 10, No. 6, 2005, pp. 749-757. doi: 10.1061/(ASCE)1084-0702(2005)10:6(749)

10. Harries, K. A.; Ricles, J. M.; Pessiki, S.; and Sause, R., “Seismic Retrofit of Lap Splices in Nonductile Square Columns Using Carbon Fiber-Reinforced Jackets,” ACI Structural Journal, V. 103, No. 6, Nov.-Dec. 2006, pp. 874-884.

11. ElGawady, M.; Endeshaw, M.; McLean, D.; and Sack, R., “Retrofitting of Rectangular Columns with Deficient Lap Splices,” Journal of Composites for Construction, ASCE, V. 14, No. 1, 2010, pp. 22-35. doi: 10.1061/(ASCE)CC.1943-5614.0000047

12. Harajli, M., “Seismic Behavior of RC Columns with Bond-Critical Regions: Criteria for Bond Strengthening Using External FRP Jackets,” Journal of Composites for Construction, ASCE, V. 12, No. 1, 2008, pp. 69-79. doi: 10.1061/(ASCE)1090-0268(2008)12:1(69)

13. Bournas, D. A.; Triantafillou, T. C.; Zygouris, K.; and Stavropoulos, F., “Textile-Reinforced Mortar Versus Frp Jacketing in Seismic Retrofitting of RC Columns with Continuous or Lap-Spliced Deformed Bars,” Journal of Composites for Construction, ASCE, V. 13, No. 5, 2009, pp. 360-371. doi: 10.1061/(ASCE)CC.1943-5614.0000028

14. Pam, H. J., and Ho, J. C., “Effects of Steel Lap Splice Locations on Strength and Ductility of Reinforced Concrete Columns,” Advances in Structural Engineering, V. 13, No. 1, 2010, pp. 199-214. doi: 10.1260/1369-4332.13.1.199

15. Chowdhury, S.R., and Orakcal, K., “Analytical Modeling of Columns with Inadequate Lap Splices,” ACI Structural Journal, V. 110, No. 5, Sept.-Oct. 2016, pp. 735-744.

16. Grammatikou, S.; Biskinis, D.; and Fardis, M. N., “Effect of Load Cycling, FRP Jackets, and Lap-Splicing of Longitudinal Bars on the Effective Stiffness and Ultimate Deformation of Flexure-Controlled RC Members,” Journal of Structural Engineering, ASCE, V. 144, No. 6, 2018, pp. 1-19. (04018056)

17. ACI Committee 374, “Acceptance Criteria for Moment Frames Based on Structural Testing and Commentary (ACI 374.1-05),” American Concrete Institute, Farmington Hills, MI, 2005, pp. 1-9.

18. Lehman, D. E., and Moehle, J. P., “Seismic Performance of Well-Confined Concrete Bridge Columns,” PEER-1998/01, Pacific Earthquake Engineering Research Center, University of California, Berkeley, Berkeley, CA, 1998, pp. 1-316.

19. Setzler, E. J., and Sezen, H., “Model for the Lateral Behavior of Reinforced Concrete Columns Including Shear Deformations,” Earthquake Spectra, V. 24, No. 2, 2008, pp. 493-511. doi: 10.1193/1.2932078


ALSO AVAILABLE IN:

Electronic Structural Journal



  

Edit Module Settings to define Page Content Reviewer