Creep Tests of Two-Way Prestressed Concrete
Author(s):
Howard L. Furr
Publication:
Journal Proceedings
Volume:
64
Issue:
6
Appears on pages(s):
288-294
Keywords:
creep (materials);lightweight aggregate concretes;losses;prestressed concrete; research;shrinkage;slabs (nonmetallic)
DOI:
10.14359/7566
Date:
6/1/1967
Abstract:
Creep tests on small prestressed structural lightweight concrete slabs are discussed. Three 2 x 2 ft x 2 ‘/2 in. slabs prestressed equally in two directions to 1000, 2000, and 3000 psi, respectively, were gaged for strain. One slab of similar dimensions was prestressed to 2000 psi on one direction. Small 3 x 3 x 1 6-in. prisms were spring loaded axially to the same initial stresses as the prestressed slabs. It was found that creep in the 2000 psi two-way slab was virtually the same as that in the 2000 psi one-way slab. Prestress losses after 313 days were about 25 and 30 percent in the 2000 and 3000 psi slabs, respectively.