In today’s market, it is imperative to be knowledgeable and have an edge over the competition. ACI members have it…they are engaged, informed, and stay up to date by taking advantage of benefits that ACI membership provides them.
Read more about membership
Learn More
Become an ACI Member
Founded in 1904 and headquartered in Farmington Hills, Michigan, USA, the American Concrete Institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensus-based standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete design, construction, and materials, who share a commitment to pursuing the best use of concrete.
American Concrete Institute 38800 Country Club Dr. Farmington Hills, MI 48331-3439 USA
Phone: 1.248.848.3700 Fax: 1.248.848.3701 Staff Directory
Email Support
Feedback via Email Phone: 1.248.848.3800
Home > Publications > International Concrete Abstracts Portal
The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.
Title: Marine Corrosion Behavior of Reinforced Concrete Exposed at Tokyo Bay
Author(s): M. Makita, Y. Mori, and K. Katawaki
Publication: Special Publication
Volume: 65
Issue:
Appears on pages(s): 271-290
Keywords: chlorides; cover; corrosion; cracking (fracturing); crack width and spacing; electrical resistance; exposure; marine atmospheres; reinforced concrete; reinforcing steels; sea water; specimens; thickness; water-cement ratio.
Date: 8/1/1980
Abstract:Reinforced concrete test specimens of 23 kinds were exposed on the sea in Tokyo Bay for about 1000 days, and corrosion of the reinforcement in the concrete was measured. As the result, the following were disclosed: 1) Corrosion of the reinforcement in concrete is affected greatly by both the cover thickness and water- cement ratio; 2) Test specimens exposed from seawater into air had no corrosion produced in the submerged portion but had corrosion produced at a particular height above the sea surface; 3) Test specimens exposed in air above the sea surface had irregular partial corrosion produced; 4) Electric resistance of theconcrete where corrosion occurred was low, and so was the natural potential of the reinforcing steel, and the corrosion occurred at valleys of the distributions of electric resistance and natural potential; and 5) From the foregoing, partial corrosion of the reinforcing steel in concrete is due to macro-corrosive current flow as the potential distribution in the reinforcing steel had peaks and valleys produced.