Showing 1-5 of 131 Abstracts search results

Document: 

SP-360_04

Date: 

March 1, 2024

Author(s):

Ali Alatify and Yail J. Kim

Publication:

Symposium Papers

Volume:

360

Abstract:

The serviceability and ultimate limit states of a concrete member are reliant upon the bond of reinforcement. The performance of glass fiber reinforced polymer (GFRP) reinforced concrete structures is influenced by multiple parameters and one of these parameters is the bond length of GFRP rebars. The scope of the present research is to experimentally study the effects of fully and partially bonded rebars on the load-bearing capacity and cracking of GFRP-reinforced concrete beams. The beams with partially bonded reinforcement show reduced capacities compared with those with fully bonded reinforcement, and the former reveals localized cracks. The partially bonded beams fail as a result of concrete splitting, while their fully bonded counterparts fail by concrete crushing.

DOI:

10.14359/51740616


Document: 

SP-360_19

Date: 

March 1, 2024

Author(s):

Huifeng Qian, Wendell Harriman II., P.E.

Publication:

Symposium Papers

Volume:

360

Abstract:

Fiber reinforced polymer (FRP) composite rebar is a non-metallic concrete reinforcement alternative that has been successfully deployed in hundreds of structural applications globally. The increasing demand for FRP rebar as a metal alternative is driven by its unique value proposition, including lightweight, high strength, magnetic transparency, and most significantly, corrosion resistance. FRP rebar is fabricated through pultrusion, a high throughput composite fabrication process in which, resin-impregnated fiber undergoes rapid cure when pulled through a heated furnace. Considering the open nature of the open pultrusion process, expansion of production capacity for FRP rebar manufacturing demands the use of advanced resins that are free from Volatile Organic Compounds (VOCs), enable high throughput production, and deliver an outstanding translation of fiber properties following cure. In this work, we will present an epoxy system that is inherently VOC Free and is tailored to enable high throughput manufacturing of glass fiber reinforced polymer (GFRP) rebar at scale. Furthermore, the rapid formation of highly crosslinked structures achieved with this resin system during pultrusion is found to enable outstanding fiber property translation resulting in high modulus (>70 GPa) and corrosion resistance (>80 % tensile strength retention without load) that exceeds existing standards such as ASTM D7957.

DOI:

10.14359/51740631


Document: 

SP-360_23

Date: 

March 1, 2024

Author(s):

Raphael Kampmann, Tim Rauert, Niklas Pelka, und Bastian Franzenburg

Publication:

Symposium Papers

Volume:

360

Abstract:

Corrosion of reinforcement steel is a major issue for many structural concrete components, because it leads to strength reduction and may significantly reduce the service life. For this reason, fiber-reinforced polymer rebars (FRP rebars) have been developed, as they represent a viable alternative that may replace reinforcing steel for structures that are particularly susceptible to corrosion issues. However, structural design philosophies for these new materials are still in development and further research is needed to implement FRP rebars properly and safely in design codes but also to ensure that design calculations properly predict the actual behavior and performance of FRP reinforced structures.

This study was conducted to evaluate the strength and structural deformation behavior of flexural beams that were designed according to Eurocode 2 and, for comparison, according to different design methods pro-posed for FRP reinforced structures. With regard to the development of a uniform design concept for alternative reinforcement materials existing in Germany/Europe, different bending design concepts includ-ing the serviceability limit state were evaluated. In addition, the theoretically calculated and predicted strength/deformation were compared to the experimentally obtained measurements. A total of 15 flexu-ral beams, with ans overall length of 4.5 m (177 in.), a width of 200 mm (7.8 in.), and a height of 400 mm (15.8 in.), were cast; three of these beams (designed according to Eurocode 2) featured traditional steel rein-forcement, to serve as control group. The remaining 12 flexural beams were evenly allocated to capture the two alternative reinforcement materials, while generating three different reinforcement distribution patterns with comparable reinforcement ratios (equivalent cross-sectional areas). Thus, a total of six subgroups –three with GFRP and three with BFRP – each with two specimens, were analized. To test all beam in pure bending and to eliminate the influence from shear forces, two equally increasing loads were applied at the (longitudinal) third-points of the beams. Both deflections and loads were measured at several points to evaluate the structural performance of the FRP reinforced structural members.

The results showed that the deflection of the glass fiber reinforced bars at the design load capacity measured twice as much as the deflection of the control group. Almost three times as much deflection (at the same load) was observed for the concrete beams reinforced with basalt fiber rebars. In addition, it was observed that the concrete beams with glass and basalt fiber reinforcement bars showed a nearly elastic-elastic behavior up to the point of failure, whereas the steel-reinforced concrete beams showed an elastic-plastic behavior. However, the deformational behavior differed between the various beam types. While the prevailing equations properly captured the post-cracking performance of traditionally reinforced concrete beams, they do not adequately predict the deflections of FRP reinforced concrete beams. From the measurements and analyses, it was concluded that the serviceability limit state (SST) is more critical than the ultimate limit state (LTS) for the design of concrete flexural beams reinforced with FRP rebars.

DOI:

10.14359/51740635


Document: 

SP-360_08

Date: 

March 1, 2024

Author(s):

Nadia Nassif , M. Talha Junaid, Salah Altoubat, Mohamed Maalej, and Samer Barakat

Publication:

Symposium Papers

Volume:

360

Abstract:

Fiber-reinforced polymer (FRP) bars can serve as an appropriate substitute for steel rebar due to their lightweight, high strength, and good corrosion resistance. Nevertheless, the long-term success of FRP bars as promising reinforcement in concrete depends on understanding the bond between FRP bars and concrete. ACI 440.1R-15 recommends utilizing CSA S806-12 Annex S ‘‘Test Method for Determining the Bond-Dependent Coefficient of FRP Rods” for estimating the design value of the bond-dependent coefficient (kb). However, this testing method requires a four-point loaded 3.0-meter-long beam with continuous assessment of developed crack width. Due to the complexity of the test, studies were scarce in assessing the factors affecting the kb. Therefore, this study aimed to relate the experimental kb obtained from large-scale testing to a relatively simpler bond strength value, τu , obtained from smaller-scale FRP pull-out test. The relation was established utilizing data collection for both tests from experimental studies. Three machine learning techniques (Ensembled Trees Artificial Neural Network and Gaussian Process Machines) were then applied to mimic and understand the complex bond-behaviour at varying FRP and concrete properties. The results have shown promising relation (R2>0.8) between kb and τu for different surface textures and fibre types.

DOI:

10.14359/51740620


Document: 

SP-360_02

Date: 

March 1, 2024

Author(s):

John J. Myers

Publication:

Symposium Papers

Volume:

360

Abstract:

The American Concrete Institute (ACI) 440.1R-15 Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars linearly reduces the bar stress and thereby pull-out capacity of FRP bars to zero from an embedment length at 20 bar diameters (db) or less. Most experimental research and data examine the development length of various FRP bars at longer, more traditional, embedment lengths. A database was created from select available data in literature to compare to empirical standards. This investigation examines the bond performance of short embedded FRP bars into concrete considering a pull-out failure mode to expand the understanding of short embedded FRP bars into concrete. Based upon the database collected, for the glass fiber-reinforced polymer (GFRP) rebars, the current 440.1R appear quite conservative. For the basalt fiber-reinforced polymer (BFRP) rebar database collected, the current ACI 440.1R-15 provisions appear unconservative for a statistically significant number of the specimen test results within the database. In the case of the carbon fiber-reinforced polymer (CFRP) database, which is quite limited, the data appears to develop considerably less bond strength than the current 440.1R provisions might suggest which requires deeper investigation for the case of short embedment length bonded CFRP bars.

DOI:

10.14359/51740614