ABOUT THE INTERNATIONAL CONCRETE ABSTRACTS PORTAL

  • The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

International Concrete Abstracts Portal

  


Title: Finite Element Analyses of Seismic Response of a 22-story RC Wall Building subjected to Drying Shrinkage Cracking and Application of SCRPCC

Author(s): Kitazawa, K.; Sato, Y.; Naganuma, K.; Kaneko, Y.

Publication: Symposium Paper

Volume: 343

Issue:

Appears on pages(s): 272-281

Keywords: Drying shrinkage crack, Steel chip reinforced polymer cementitious composite, 3D FEM

DOI:

Date: 10/1/2020

Abstract:
This paper attempts to investigate the effectiveness of Steel Chip Reinforced Polymer Cementitious Composite (SCRPCC) to reduce the seismic drift of high rise building by employing finite element method. Steel chips are produced when a steel plate is precisely machined on a numerically controlled lathe. To verify the influence of drying shrinkage on the structural performance of entire buildings, seismic response analyses of a 22-story RC wall building subject to drying shrinkage cracking are conducted. The analyzed building was damaged in 1985 Mexico Earthquake. In the analyses, drying shrinkage is considered by conducting the drying shrinkage cracking analyses before dynamic seismic vibration analyses to examine the influence of drying shrinkage. For each case of the analyses, two kinds of materials are used; ordinary concrete and SCRPCC. The shrinkage of 8,400-day drying period induces cracks in the walls of top floor as well as the first floor. The maximum drift of the building is increased in the NS direction by the shrinkage cracking while reduced in the EW direction. The maximum total drift of the building during the seismic vibration is reduced by 3.5% in the NS direction and 8.9% in the EW direction by using the SCRPCC instead of the ordinary concrete. The average crack width of the building is reduced by 11.1% by the SCRPCC.