Title:
Modeling Parameters and Acceptance Criteria for RC Walls: Phase III – Diagonal Shear-Controlled Walls (Prepublished)
Author(s):
Saman A. Abdullah, John W. Wallace, Wassim M. Ghannoum, Mohamed M. Talaat, Garrett Hagen, and Laura Lowes
Publication:
Structural Journal
Volume:
Issue:
Appears on pages(s):
Keywords:
acceptance criteria; concrete walls; modeling parameters; retrofit; seismic evaluation; shear-controlled
DOI:
10.14359/51752072
Date:
9/17/2026
Abstract:
Most of the provisions for concrete structural walls in ASCE/SEI 41-17 were developed in the late 1990s based on limited experimental data and judgment for FEMA-273 (1997a) and FEMA-274 (1997b). The only exception being the modeling parameters and acceptance criteria of shear-controlled walls, which were updated for ASCE/SEI 41-06 Supplement 1 (Elwood et al., 2007). As a result, the wall provisions tend to be, in many cases, inaccurate and conservative, and thus can produce uneconomical retrofit schemes. This study involves utilizing available experimental data from a large wall test database (more than 1,100 wall tests) and new information on the performance of structural walls to develop modeling parameters and acceptance criteria for diagonal shear-controlled walls that will produce improved seismic assessments of wall buildings. Assessment outcomes between the provisions of ASCE/SEI 41-17 and the proposed provisions showed that the current provisions in ASCE/SEI 41-17 are, in many cases, overly conservative for many structures.