Title: Seismic Performance of Precast Concrete Column-Foundation Joints with Dry Strong Connections (Prepublished)

Author(s): Seon-Hoon Kim, Deuckhang Lee, and Wei Zhang

Publication: Structural Journal

Volume:

Issue:

Appears on pages(s):

Keywords: column-foundation connection; dry connection; emulative detailing; precast concrete; strong-connection design

DOI: 10.14359/51752064

Date: 9/16/2026

Abstract:
This study investigates the seismic performance of precast concrete column-foundation connections incorporating dry mechanical splices, so-called column shoes, designed as strong connections per ACI CODE-318-25 and ACI PCI-319-25. Two precast concrete connection specimens—designated PF (full-dry connections, bolted-column shoe only) and PS (semi-dry connections, bolted column shoe combined with grouted splice sleeves)—were tested alongside a reinforced concrete (RC) control specimen with a monolithic connection detail under quasi-static reversed cyclic loading. The precast specimens were designed to satisfy the strong-connection details of the precast concrete special moment frame system to promote the plastic hinge formation outside the mechanical splices. Their seismic response was compared with that of the RC control specimen to justify the emulative seismic performance. The precast specimens exhibited comparable cyclic responses, including the lateral strength, hysteretic behavior, and deformation capacity to that of the monolithic specimen. Strain responses in longitudinal reinforcements in the precast concrete columns across the joint showed that inelastic deformation was relocated to the intended plastic hinge region rather than the location of the mechanical splices. Although the precast specimens exhibited slightly lower post-peak strength, primarily due to localized grout damage for dry connections, the overall seismic performance fully satisfied the acceptance criteria of ACI 374.1. The results indicate that bolted-type dry mechanical splices, when designed using the strong-connection concept, can provide code-compliant seismic performance under severe cyclic inelastic demands while preventing premature damage concentration in the splice region.


ALSO AVAILABLE IN:

Electronic Structural Journal